EUVIMEDEUVIMED entdecken
Systematische Übersicht

Can Artificial Intelligence Accurately Detect Urinary Stones? A Systematic Review

Kann künstliche Intelligenz Harnsteine zuverlässig erkennen? Eine systematische Übersicht

Frédéric Panthier iD, Alberto Melchionna, Hugh Crawford-Smith, Yiannis Phillipou, Simon Choong, Vimoshan Arumuham, Sian Allen, Clare Allen, Daron Smith

Journal of Endourology · 2024-08 · 38 (8) · 725-740

DOI: 10.1089/end.2023.0717 ↗

Auf einen Blick

Eine systematische Übersicht von 12 Studien zeigt, dass KI Harnsteine in der NCCT erkennen kann. Die berichteten Leistungswerte lagen breit auseinander.

Fragestellung

Wie gut erkennt künstliche Intelligenz Harnsteine oder misst sie in originalen Studien?

Methode

Systematische Übersicht; Suche in Scopus, Web of Science, Embase und PubMed; RoB mit Cochrane RoB tool, JBI Checklist und CLAIM.

Ergebnisse

12 Studien, darunter 3 multizentrische und 9 monozentrische retrospektive Studien. Sensitivität 58,7 % bis 100 %, Spezifität 68,5 % bis 100 %, Genauigkeit 63 % bis 99,95 %, Dice-Score 83 % bis 97 %.

Einschränkungen

Nur eine Studie mit externer Validierung; 1 Studie mit hohem RoB; 11 Studien erfüllten mindestens 50 % der CLAIM-Checkpoints.

Schlussfolgerung der Autor:innen

KI-Verfahren können eine automatisierte Harnsteinerkennung aus der NCCT erreichen.

Kernaussagen

  • KI erkannte Harnsteine in der NCCT in 12 Studien
  • Leistungswerte variierten stark zwischen den Studien
  • Externe Validierung lag nur in einer Studie vor

Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.

Kurz gefasst

Systematische Übersicht in der Zeitschrift Journal of Endourology, online erschienen am 01.08.2024. Verfasst von Frédéric Panthier und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Urology, Westmoreland Street Hospital, UCLH NHS Foundation Trust, London, United Kingdom. Hauptthemen laut MEDLINE: Artificial Intelligence, Urinary Calculi. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 48 Literaturangaben.

Auf einen BlickAbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To perform a systematic review on artificial intelligence (AI) performances to detect urinary stones.

Methods

A PROSPERO-registered (CRD473152) systematic search of Scopus, Web of Science, Embase, and PubMed databases was performed to identify original research articles pertaining to AI stone detection or measurement, using search terms (“automatic” OR “machine learning” OR “convolutional neural network” OR “artificial intelligence” OR “detection” AND “stone volume”). Risk-of-bias (RoB) assessment was performed according to the Cochrane RoB tool, the Joanna Briggs Institute Checklist for nonrandomized studies, and the Checklist for Artificial Intelligence in Medical Imaging (CLAIM).

Results

Twelve studies were selected for the final review, including three multicenter and nine single-center retrospective studies. Eleven studies completed at least 50% of the CLAIM checkpoints and only one presented a high RoB. All included studies aimed to detect kidney (5/12, 42%), ureter (2/12, 16%), or urinary (5/12, 42%) stones on noncontrast computed tomography (NCCT), but 42% intended to automate measurement. Stone distinction from vascular calcification interested two studies. All studies used AI machine learning network training and internal validation, but a single one provided an external validation. Trained networks achieved stone detection, with sensitivity, specificity, and accuracy rates ranging from 58.7% to 100%, 68.5% to 100%, and 63% to 99.95%, respectively. Detection Dice score ranged from 83% to 97%. A high correlation between manual and automated stone volume ( r = 0.95) was noted. Differentiate distal ureteral stones and phleboliths seemed feasible.

Conclusions

AI processes can achieve automated urinary stone detection from NCCT. Further studies should provide urinary stone detection coupled with phlebolith distinction and an external validation, and include anatomical abnormalities and urologic foreign bodies (ureteral stent and nephrostomy tubes) cases.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Artificial IntelligenceUrinary CalculiHumansMachine LearningTomography, X-Ray Computed

Stichwörter der Autor:innen

artificial intelligenceconvolutional neural networkdetectionmachine learningurinary stonesvolume

Autor:innen und Institutionen

  • Department of Urology, Westmoreland Street Hospital, UCLH NHS Foundation Trust, London, United Kingdom.
  • Sorbonne University GRC Urolithiasis No. 20 Tenon Hospital, Paris, France.
  • Progressive Endourological Association for Research and Leading Solutions (PEARLS), Paris, France.
  • PIMM, UMR 8006 CNRS-Arts et Métiers ParisTech, Paris, France.
  • Department of Radiology, University College London Hospitals, London, United Kingdom.
  • Endourology Academy.

ORCID-Profile: Frédéric Panthier

Zitieren

APA

Panthier, F., Melchionna, A., Crawford-Smith, H., Phillipou, Y., Choong, S., Arumuham, V., Allen, S., Allen, C., & Smith, D. (2024). Can Artificial Intelligence Accurately Detect Urinary Stones? A Systematic Review. Journal of Endourology, 38(8), 725-740. https://doi.org/10.1089/end.2023.0717

Vancouver

Panthier F, Melchionna A, Crawford-Smith H, Phillipou Y, Choong S, Arumuham V, et al. Can Artificial Intelligence Accurately Detect Urinary Stones? A Systematic Review. Journal of Endourology. 2024;38(8):725-740. doi:10.1089/end.2023.0717

BibTeX
@article{Panthier2024,
  author = {Panthier, Frédéric and Melchionna, Alberto and Crawford-Smith, Hugh and Phillipou, Yiannis and Choong, Simon and Arumuham, Vimoshan and Allen, Sian and Allen, Clare and Smith, Daron},
  title = {Can Artificial Intelligence Accurately Detect Urinary Stones? A Systematic Review},
  journal = {Journal of Endourology},
  year = {2024},
  volume = {38},
  number = {8},
  pages = {725--740},
  doi = {10.1089/end.2023.0717}
}
Kostenlos starten →