EUVIMEDEUVIMED entdecken
Crossref

Automated Analysis of Split Kidney Function from CT Scans Using Deep Learning and Delta Radiomics

Ramon Luis Correa-Medero iD, Jiwoong Jeong, Bhavik Patel, Imon Banerjee, Haidar Abdul-Muhsin

Journal of Endourology · 2024

DOI: 10.1089/end.2023.0488 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Endourology, 2024. Verfasst von Ramon Luis Correa-Medero und 4 weiteren Autor:innen. Beteiligte Einrichtung: School of Computing and Augmented Intelligence, Arizona State University, Arizona, USA. Hauptthemen laut MEDLINE: Deep Learning, Tomography, X-Ray Computed, Kidney. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 17 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Differential kidney function assessment is an important part of preoperative evaluation of various urological interventions. It is obtained through dedicated nuclear medical imaging and is not yet implemented through conventional Imaging.

Objective

We assess if differential kidney function can be obtained through evaluation of contrast-enhanced computed tomography(CT) using a combination of deep learning and (2D and 3D) radiomic features.

Methods

All patients who underwent kidney nuclear scanning at Mayo Clinic sites between 2018–2022 were collected. CT scans of the kidneys were obtained within a 3-month interval before or after the nuclear scans were extracted. Patients who underwent a urological or radiological intervention within this time frame were excluded. A segmentation model was used to segment both kidneys. 2D and 3D radiomics features were extracted and compared between the two kidneys to compute delta radiomics and assess its ability to predict differential kidney function. Performance was reported using receiver operating characteristics, sensitivity, and specificity.

Results

Studies from Arizona & Rochester formed our internal dataset ( n = 1,159). Studies from Florida were separately processed as an external test set to validate generalizability. We obtained 323 studies from our internal sites and 39 studies from external sites. The best results were obtained by a random forest model trained on 3D delta radiomics features. This model achieved an area under curve (AUC) of 0.85 and 0.81 on internal and external test sets, while specificity and sensitivity were 0.84,0.68 on the internal set, 0.70, and 0.65 on the external set.

Conclusion

This proposed automated pipeline can derive important differential kidney function information from contrast-enhanced CT and reduce the need for dedicated nuclear scans for early-stage differential kidney functional assessment. Clinical Impact: We establish a machine learning methodology for assessing differential kidney function from routine CT without the need for expensive and radioactive nuclear medicine scans.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Deep LearningTomography, X-Ray ComputedKidneyHumansFemaleMaleMiddle AgedAgedKidney Function TestsAutomationImage Processing, Computer-AssistedRadiomics

Stichwörter der Autor:innen

CT imagingdifferential functionradiomicssegmentation

Autor:innen und Institutionen

  • School of Computing and Augmented Intelligence, Arizona State University, Arizona, USA.
  • Department of Radiology, Mayo Clinic Hospital, Phoenix, Arizona, USA.
  • Department of Urology, Mayo Clinic Hospital, Phoenix, Arizona, USA.

ORCID-Profile: Ramon Luis Correa-Medero

Zitieren

APA

Correa-Medero, R. L., Jeong, J., Patel, B., Banerjee, I., & Abdul-Muhsin, H. (2024). Automated Analysis of Split Kidney Function from CT Scans Using Deep Learning and Delta Radiomics. Journal of Endourology. https://doi.org/10.1089/end.2023.0488

Vancouver

Correa-Medero RL, Jeong J, Patel B, Banerjee I, Abdul-Muhsin H. Automated Analysis of Split Kidney Function from CT Scans Using Deep Learning and Delta Radiomics. Journal of Endourology. 2024. doi:10.1089/end.2023.0488

BibTeX
@article{CorreaMedero2024,
  author = {Correa-Medero, Ramon Luis and Jeong, Jiwoong and Patel, Bhavik and Banerjee, Imon and Abdul-Muhsin, Haidar},
  title = {Automated Analysis of Split Kidney Function from CT Scans Using Deep Learning and Delta Radiomics},
  journal = {Journal of Endourology},
  year = {2024},
  doi = {10.1089/end.2023.0488}
}
Kostenlos starten →