EUVIMEDEUVIMED entdecken
Crossref

Simplified Meal Management in Adults Using an Advanced Hybrid Closed-Loop System

Noga Minsky iD, Roy Shalit iD, Andrea Benedetti, Maya Laron-Hirsh, Ohad Cohen iD, Natalie Kurtz, Anirban Roy iD, Benyamin Grosman, Amir Tirosh

Diabetes Technology & Therapeutics · 2025-01 · 27 (1) · 27-33

DOI: 10.1089/dia.2024.0224 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Diabetes Technology & Therapeutics, online erschienen am 08.01.2025. Verfasst von Noga Minsky und 8 weiteren Autor:innen. Beteiligte Einrichtung: Division of Endocrinology, Diabetes and Metabolism, Sheba Medical Center, Tel-Hashomer, Israel. Hauptthemen laut MEDLINE: Diabetes Mellitus, Type 1, Blood Glucose, Meals, Hypoglycemic Agents. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 22 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The advanced hybrid closed-loop (AHCL) algorithm combines automated basal rates and corrections yet requires meal announcement for optimal performance, which poses a challenge for some. We aimed to compare glucose control in adults with type 1 diabetes (T1D) using the MiniMed TM 780G AHCL system, utilizing simplified meal announcement versus precise carbohydrate (CHO) counting.

Methods

In a study involving 14 adults with T1D, we evaluated glycemic control during a 13-week “precise phase,” followed by two 3- to 4-week simplified meal announcement phases: “fixed one-step” (preset of one personalized fixed CHO amount) and “multistep” (entry of multiples of one, two, or three of these presets depending on meal size estimate).

Results

The mean age was 45.7 ± 12.4, and 10 participants were male (71%). Mean baseline HbA1c was 6.8% ± 1.2% and time in range (TIR) was 67.5% ± 16.7%. Comparing the fixed one-step to the precise study phase, TIR was similar (75.4 ± 13% vs. 77.7 ± 9%, P = 0.12), and glucose management indicator (GMI) was slightly higher (6.8 ± 0.4 vs. 6.6 ± 0, P = 0.01). Furthermore, there was less level 1 and 2 hypoglycemia (1.6 ± 1% vs. 2.8 ± 2%, P = 0.03 and 0.3 ± 5% vs. 0.65 ± 1%, P = 0.08) but slightly more level 1 and 2 hyperglycemia (17.1 ± 8% vs. 15.0 ± 7%, P = 0.05 and 5.5 ± 5% vs. 3.6 ± 3%, P = 0.04). When comparing the multistep with the precise phase, GMI was identical (6.6%) and TIR superior (80.5 ± 10% vs. 77.7 ± 9%, P = 0.02). Additionally, there was less level 1 hypoglycemia (1.9 ± 1% vs. 2.8 ± 2%, P = 0.01) and a trend for less level 2 hypoglycemia (0.4 ± 0.7% vs. 0.65 ± 1%, P = 0.08).

Conclusions

A simplified meal announcement strategy for adults using the MiniMed 780G system, relying on three increments of a fixed one-step CHO amount, may offer a way to improve glycemic control and ease self-care. For patients with more limitations, using one fixed one-step CHO amount could be a safe alternative to meeting most consensus glycemic targets.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Diabetes Mellitus, Type 1Blood GlucoseMealsHypoglycemic AgentsInsulinAlgorithmsGlycemic ControlInsulin Infusion SystemsHumansMaleFemaleAdultMiddle AgedGlycated HemoglobinBlood Glucose Self-MonitoringHypoglycemiaDietary Carbohydrates

Stichwörter der Autor:innen

MM780GTMautomated insulin deliverycarbohydrate countingmeal announcement

Substanzen

Blood GlucoseHypoglycemic AgentsInsulinGlycated HemoglobinDietary Carbohydrateshemoglobin A1c protein, human

Autor:innen und Institutionen

  • Division of Endocrinology, Diabetes and Metabolism, Sheba Medical Center, Tel-Hashomer, Israel.
  • Medtronic, Northridge, California, USA.
  • Faculty of Medicine, Tel-Aviv University, Tel-Aviv, Israel.

ORCID-Profile: Noga Minsky, Roy Shalit, Ohad Cohen, Anirban Roy

Zitieren

APA

Minsky, N., Shalit, R., Benedetti, A., Laron-Hirsh, M., Cohen, O., Kurtz, N., Roy, A., Grosman, B., & Tirosh, A. (2025). Simplified Meal Management in Adults Using an Advanced Hybrid Closed-Loop System. Diabetes Technology & Therapeutics, 27(1), 27-33. https://doi.org/10.1089/dia.2024.0224

Vancouver

Minsky N, Shalit R, Benedetti A, Laron-Hirsh M, Cohen O, Kurtz N, et al. Simplified Meal Management in Adults Using an Advanced Hybrid Closed-Loop System. Diabetes Technology & Therapeutics. 2025;27(1):27-33. doi:10.1089/dia.2024.0224

BibTeX
@article{Minsky2025,
  author = {Minsky, Noga and Shalit, Roy and Benedetti, Andrea and Laron-Hirsh, Maya and Cohen, Ohad and Kurtz, Natalie and Roy, Anirban and Grosman, Benyamin and Tirosh, Amir},
  title = {Simplified Meal Management in Adults Using an Advanced Hybrid Closed-Loop System},
  journal = {Diabetes Technology & Therapeutics},
  year = {2025},
  volume = {27},
  number = {1},
  pages = {27--33},
  doi = {10.1089/dia.2024.0224}
}
Kostenlos starten →