Fachartikel in der Zeitschrift Diabetes Technology & Therapeutics, online erschienen am 05.02.2024. Verfasst von Pratik Choudhary und 5 weiteren Autor:innen. Beteiligte Einrichtung: Kings College Hospital NHS Foundation Trust, London, United Kingdom. Hauptthemen laut MEDLINE: Blood Glucose Self-Monitoring, Diabetes Mellitus, Type 1. Die Arbeit wurde bisher 80-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Introduction
The present report celebrates the benchmarking of 100,000 MiniMed™ 780G system users in Europe, Middle East, and Africa (EMEA) and summarizes the major insights into the usability and outcomes of this system.
Methods
Carelink Personal data (August 2020–August 2023) of users living in EMEA were analyzed. Continuous glucose monitoring-based endpoints were aggregated for (1) the full cohort and (2) a 12-month longitudinal cohort. Subanalyses were done for users on optimal settings (those spending ≥95% of time with glucose target of 100 mg/dL, and ≥95% of time with active insulin time of 2 h), for self-reported age groups (≤15 and ≥56 years) and for various countries/regions.
Results
Data from 101,629 users (34 countries) were analyzed. Mean time in range (TIR) was 72.3%, glucose management indicator (GMI) was 7%, time below 70 mg/dL (TBR70) was 2.0% and time below 54 mg/dL (TBR54) was 0.4%. In terms of international targets, 59.6% of users achieved a GMI 70%, 88.4% a TBR70 < 4%, and 90.0% a TBR54 < 1%. Data improved impressively in optimal setting users (TIR = 78.8%, and users reaching TIR >70% = 86.3%) while safety remained (TBR70 = 2.2% and TBR54 = 0.4%). Data showed consistency across self-reported age groups and geographies. In the longitudinal cohort, TIR reached 75.5% in the first month and remained 73.3% or higher over the 12-month period.
Conclusion
Over 100,000 users of the MiniMed™ 780G system have demonstrated consistency in achieving target control of glycemia.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Kings College Hospital NHS Foundation Trust, London, United Kingdom.
- Leicester Diabetes Center, University of Leicester, Leicester, United Kingdom.
- Medtronic Diabetes, Medtronic International Trading Sàrl, Tolochenaz, Switzerland.
ORCID-Profile: Tim van den Heuvel, Ohad Cohen
Zitieren
APA
Choudhary, P., Arrieta, A., van den Heuvel, T., Castañeda, J., Smaniotto, V., & Cohen, O. (2024). Celebrating the Data from 100,000 Real-World Users of the MiniMed™ 780G System in Europe, Middle East, and Africa Collected Over 3 Years: From Data to Clinical Evidence. Diabetes Technology & Therapeutics, 26(3_suppl), 32-37. https://doi.org/10.1089/dia.2023.0433
Vancouver
Choudhary P, Arrieta A, van den Heuvel T, Castañeda J, Smaniotto V, Cohen O. Celebrating the Data from 100,000 Real-World Users of the MiniMed™ 780G System in Europe, Middle East, and Africa Collected Over 3 Years: From Data to Clinical Evidence. Diabetes Technology & Therapeutics. 2024;26(3_suppl):32-37. doi:10.1089/dia.2023.0433
BibTeX
@article{Choudhary2024,
author = {Choudhary, Pratik and Arrieta, Arcelia and van den Heuvel, Tim and Castañeda, Javier and Smaniotto, Vittorino and Cohen, Ohad},
title = {Celebrating the Data from 100,000 Real-World Users of the MiniMed™ 780G System in Europe, Middle East, and Africa Collected Over 3 Years: From Data to Clinical Evidence},
journal = {Diabetes Technology & Therapeutics},
year = {2024},
volume = {26},
number = {3_suppl},
pages = {32--37},
doi = {10.1089/dia.2023.0433}
}
EUVIMED