EUVIMEDEUVIMED entdecken
Open Access

Pulse Lavage and Electrical Fields to Remove Biofilms from Cobalt-Chrome Surfaces: An In Vitro Study

Martí Bernaus iD, Yuly López, Sara M Soto, Adrián Bermúdez-Castel, Jose Antonio Calero, Diego Torres, Margarita Veloso, Lluis Font-Vizcarra

Bioelectricity · 01.03.2025 · 7 (1) · 71-75

DOI: 10.1089/bioe.2024.0027 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Bioelectricity, online erschienen am 18.03.2025. Verfasst von Martí Bernaus und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics and Traumatology, Osteoarticular Infection Unit, Hospital Universitari Mutua Terrassa, Barcelona, Spain. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

With the increased use of metallic devices in medical disciplines, the number of potential complications has also risen. Orthopedic implant-related infections are a serious complication often requiring a combination of surgical and prolonged antibiotic treatment. Biofilms play an important role in implant-related infections, and many different strategies have been studied to remove it. The purpose of our study was to evaluate the effectiveness of electrical fields and pulse lavage to remove S. epidermidis biofilm from metallic surfaces used in joint arthroplasty.

Methods

We compared five different models and combination treatments in an in vitro scenario to remove the biofilm. Five different models were compared with a model without treatment (control): (a) low-pressure pulse lavage, (b) high-pressure pulse lavage, (c) pulsed electrical fields, (d) low-pressure pulse lavage in combination with pulsed electrical fields, and (e) high-pressure pulse lavage in combination with pulsed electrical fields. Electrical fields were applied using 25 pulses at 15 V. Each pulse lasted 0.1 s and was applied every 0.5 s for a total exposure time of 12.5 s. The exposure time for irrigation was set at 25 s.

Results

The most effective model for removing biofilm from cobalt-chrome surfaces was a combination of high-pressure pulse lavage and electrical fields.

Conclusion

Our study results suggest the use of pulsed electrical fields is effective at removing biofilm and that our tested conditions could be translated to a clinical scenario involving infected medical devices.

Schlagwörter

Stichwörter der Autor:innen

biofilmelectrical fieldsimplant infectionpulse lavage

Autor:innen und Institutionen

  • Department of Orthopaedics and Traumatology, Osteoarticular Infection Unit, Hospital Universitari Mutua Terrassa, Barcelona, Spain.
  • Barcelona Institute for Global Health (ISGlobal), Universitat de Barcelona, Barcelona, Spain.
  • CIBER Enfermedades Infecciosas (CIBERINFEC), Instituto de Salud Carlos III, Madrid, Spain.
  • Innovative Minds S.L., Terrassa, Barcelona, Spain.
  • AMES PM Tech Centre, Sant Vicenç dels Horts, Barcelona, Spain.
  • Department of Orthopaedics and Traumatology, Hospital Moisés Broggi and Hospital General de l'Hospitalet, Consorci Sanitari Integral, Barcelona, Spain.

ORCID-Profile: Martí Bernaus

Zitieren

APA

Bernaus, M., López, Y., Soto, S. M., Bermúdez-Castel, A., Calero, J. A., Torres, D., Veloso, M., & Font-Vizcarra, L. (2025). Pulse Lavage and Electrical Fields to Remove Biofilms from Cobalt-Chrome Surfaces: An In Vitro Study. Bioelectricity, 7(1), 71-75. https://doi.org/10.1089/bioe.2024.0027

Vancouver

Bernaus M, López Y, Soto SM, Bermúdez-Castel A, Calero JA, Torres D, et al. Pulse Lavage and Electrical Fields to Remove Biofilms from Cobalt-Chrome Surfaces: An In Vitro Study. Bioelectricity. 2025;7(1):71-75. doi:10.1089/bioe.2024.0027

BibTeX
@article{Bernaus2025,
  author = {Bernaus, Martí and López, Yuly and Soto, Sara M and Bermúdez-Castel, Adrián and Calero, Jose Antonio and Torres, Diego and Veloso, Margarita and Font-Vizcarra, Lluis},
  title = {Pulse Lavage and Electrical Fields to Remove Biofilms from Cobalt-Chrome Surfaces: An In Vitro Study},
  journal = {Bioelectricity},
  year = {2025},
  volume = {7},
  number = {1},
  pages = {71--75},
  doi = {10.1089/bioe.2024.0027}
}
Kostenlos starten →