A Comparative Study of Three Nucleic Acid Integrity Assay Systems
Biopreservation and Biobanking · 01.12.2023 · 21 (6) · 624-630
DOI: 10.1089/bio.2022.0171 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biopreservation and Biobanking, erschienen am 01.12.2023. Verfasst von Xinyi Lu und 13 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Dampness Syndrome of Chinese Medicine, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou,…. Hauptthemen laut MEDLINE: RNA, Nucleic Acids. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 13 Literaturangaben.
Abstract (Originalsprache)
Background
The measurement of nucleic acid quality, especially the analysis of integrity, is a key step for many downstream experiments in biomedical research and quality control of biomaterials. General gel electrophoresis is a traditional method for nucleic acid integrity analysis. Currently, more electrophoresis techniques are becoming standardized and automated operations with higher precision. In this study, we have evaluated the comparability and bias of the outcomes from three commercial assay systems.
Methods
Seventy-two deoxyribonucleic acid (DNA) and 67 ribonucleic acid (RNA) samples were selected for methodological comparison among different systems. The DNA Quality Number (DQN) and RNA Quality Number (RQN) of BIOptic Qsep400, DNA Quality Score (DQS) and RNA Quality Score (RQS) of PerkinElmer Labchip GX Touch HT were separately compared with the DNA Integrity Number (DIN) and RNA Integrity Number (RINe) of the Agilent 4200 TapeStation according to Clinical and Laboratory Standards Institute (CLSI) guideline (EP09-A3).
Results
The biases of the mean estimated between DQN and DIN, DQS and DIN both exceeded the acceptance criteria. The Passing-Bablok regression analysis between DQN and DIN, and the Deming regression analysis between DQS and DIN, showed the biases were both within the acceptance criteria, and the bias between DQN and DIN was smaller. For the comparisons of RQN and RINe, RQS and RINe, the regression analyses revealed the biases were both within the acceptance criteria. The bias of the mean estimated between RQS and RINe was outside of the acceptance criteria.
Conclusions
There was a good comparability in nucleic acid integrity detection between BIOptic Qsep400 and PerkinElmer Labchip GX Touch HT with the Agilent 4200 TapeStation. However, the bias and linear correlations require more attention between systems.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- State Key Laboratory of Dampness Syndrome of Chinese Medicine, The Second Affiliated Hospital of Guangzhou University of Chinese Medicine, Guangzhou, China.
- National Engineering Center of Biochip at Shanghai, Shanghai, China.
- PerkinElmer Management (Shanghai) Co., Ltd., Shanghai, China.
- Hangzhou Houze Bio-Technology Co., Ltd., Hangzhou, China.
- Agilent Technologies, Inc., Guangzhou, China.
ORCID-Profile: Qubo Chen
Zitieren
APA
Lu, X., Wei, Y., Sun, J., Xiao, B., Zhang, X., Li, W., Chen, Y., Lin, F., Zhang, L., Wang, Y., Zheng, J., Zheng, L., Zhou, X., & Chen, Q. (2023). A Comparative Study of Three Nucleic Acid Integrity Assay Systems. Biopreservation and Biobanking, 21(6), 624-630. https://doi.org/10.1089/bio.2022.0171
Vancouver
Lu X, Wei Y, Sun J, Xiao B, Zhang X, Li W, et al. A Comparative Study of Three Nucleic Acid Integrity Assay Systems. Biopreservation and Biobanking. 2023;21(6):624-630. doi:10.1089/bio.2022.0171
BibTeX
@article{Lu2023,
author = {Lu, Xinyi and Wei, Yulian and Sun, Jing and Xiao, Bo and Zhang, Xiaoyan and Li, Wanhua and Chen, Ying and Lin, Fengye and Zhang, Li and Wang, Yan and Zheng, Jing and Zheng, Lingyan and Zhou, Xingzhi and Chen, Qubo},
title = {A Comparative Study of Three Nucleic Acid Integrity Assay Systems},
journal = {Biopreservation and Biobanking},
year = {2023},
volume = {21},
number = {6},
pages = {624--630},
doi = {10.1089/bio.2022.0171}
}
EUVIMED