Vergleichsstudie

Fat Content and Energy Calculation in Pasteurized Human Milk: Comparison Between Infrared Analysis and Creamatocrit Method

Nerli Pascoal Andreassa, Fabiola Isabel Suano-Souza iD, Roseli Oselka Saccardo Sarni

Breastfeeding Medicine · 2024

DOI: 10.1089/bfm.2024.0249 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Breastfeeding Medicine, 2024. Verfasst von Nerli Pascoal Andreassa und 2 weiteren Autor:innen. Beteiligte Einrichtung: Human Milk Bank, São Bernardo do Campo Women's Hospital, Santo Andre, Brazil. Hauptthemen laut MEDLINE: Milk, Human, Pasteurization. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 28 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

This study aimed to analyze and compare the quantity of energy and fat using the infrared analysis and creamatocrit method in pasteurized human milk (HM) samples.

Methods

This cross-sectional study analyzed 1,858 pasteurized human samples from 317 mothers at a single center. Infrared transmission spectrophotometry (Miris, Human Milk Analyser [HMA], Uppsala, Sweden) and the creamatocrit method were used to evaluate the quantity of energy and fat in pasteurized HM samples.

Results

The average age of donor mothers was 29.7 ± 5.1 years, and the median duration of lactation was 22 days (interquartile range [IQ]: 7.7–59.2). Full-term births were observed in 196 (95.1%) of the women. The values of energy (difference: +8.96 kcal/dL, 95% CI: 8.52–9.44 kcal/dL; p < 0.001) and fat (difference: +0.40 g/dL, 95% CI: 0.35–0.45 g/dL; p < 0.001) in HM samples obtained by Miris were higher than those by the creamatocrit method. The energy calculated and the fat measured by Miris in the HM samples correlated moderately and directly with the obtained by creamatocrit (fat, r = 0.585; p < 0.001 and energy, r = 0.591; p < 0.01). The linear regression, adjusted for maternal age and lactation time, showed that the energy values calculated by creamatocrit were directly associated with those of Miris (energy kcal/dL = 38.43 + [0.516 × kcal/dL of creamatocrit]).

Conclusion

The energy and fat quantity of pasteurized HM samples obtained by the creamatocrit and infrared methods were significantly correlated. However, the values calculated by the creamatocrit method were significantly lower than those by the infrared analyzer.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Milk, HumanPasteurizationHumansFemaleAdultCross-Sectional StudiesBreast FeedingDietary FatsLactationEnergy IntakeSpectrophotometry, InfraredInfant, Newborn

Stichwörter der Autor:innen

creamatocrithuman milk bankinfrared methodnutrients

Substanzen

Dietary Fats

Autor:innen und Institutionen

  • Human Milk Bank, São Bernardo do Campo Women's Hospital, Santo Andre, Brazil.
  • Department of Paediatrics, Centro Universitario FMABC, Sao Paulo, Brazil.
  • Department of Paediatrics, Escola Paulista de Medicina da Universidade Federal de São Paulo (EPM-UNIFESP), Sao Paulo, Brazil.
  • Multidisciplinary Nutritional Therapy Team, Hospital da Mulher de São Bernardo do Campo, Sao Paulo, Brazil.

ORCID-Profile: Fabiola Isabel Suano-Souza

Zitieren

APA

Andreassa, N. P., Suano-Souza, F. I., & Sarni, R. O. S. (2024). Fat Content and Energy Calculation in Pasteurized Human Milk: Comparison Between Infrared Analysis and Creamatocrit Method. Breastfeeding Medicine. https://doi.org/10.1089/bfm.2024.0249

Vancouver

Andreassa NP, Suano-Souza FI, Sarni ROS. Fat Content and Energy Calculation in Pasteurized Human Milk: Comparison Between Infrared Analysis and Creamatocrit Method. Breastfeeding Medicine. 2024. doi:10.1089/bfm.2024.0249

BibTeX
@article{Andreassa2024,
  author = {Andreassa, Nerli Pascoal and Suano-Souza, Fabiola Isabel and Sarni, Roseli Oselka Saccardo},
  title = {Fat Content and Energy Calculation in Pasteurized Human Milk: Comparison Between Infrared Analysis and Creamatocrit Method},
  journal = {Breastfeeding Medicine},
  year = {2024},
  doi = {10.1089/bfm.2024.0249}
}
Kostenlos starten →