EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Room-Based Assessment of Mobile Air Cleaning Devices Using a Bioaerosol Challenge

Alan Beswick, Jodi Brookes, Iwona Rosa, Claire Bailey iD, Charlotte Beynon, Stephen Stagg, Neil Bennett

Applied Biosafety · 01.03.2023 · 28 (1) · 1-10

DOI: 10.1089/apb.2022.0028 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Applied Biosafety, online erschienen am 20.12.2022. Verfasst von Alan Beswick und 6 weiteren Autor:innen. Beteiligte Einrichtung: Health and Safety Executive Science and Research Centre, Buxton, United Kingdom. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

The widespread transmission of the SARS-CoV-2 virus has increased scientific and societal interest in air cleaning technologies, and their potential to mitigate the airborne spread of microorganisms. Here we evaluate room scale use of five mobile air cleaning devices.

Methods

A selection of air cleaners, containing high efficiency filtration, was tested using an airborne bacteriophage challenge. Assessments of bioaerosol removal efficacy were undertaken using a decay measurement approach over 3 h, with air cleaner performance compared with bioaerosol decay rate without an air cleaner in the sealed test room. Evidence of chemical by-product emission was also checked, as were total particle counts.

Results

Bioaerosol reduction, exceeding natural decay, was observed for all air cleaners. Reductions ranged between devices from 5-log reduction for the most efficacious systems. One system generated detectable ozone within the sealed test room, but ozone was undetectable when the system was run in a normally ventilated room. Total particulate air removal trends aligned with measured airborne bacteriophage decline.

Discussion

Air cleaner performance differed, and this could relate to individual air cleaner flow specifications as well as test room conditions, such as air mixing during testing. However, measurable reductions in bioaerosols, beyond natural airborne decay rate, were observed.

Conclusion

Under the described test conditions, air cleaners containing high efficiency filtration significantly reduced bioaerosol levels. The best performing air cleaners could be investigated further with improved assay sensitivity, to enable measurement of lower residual levels of bioaerosols.

Schlagwörter

Stichwörter der Autor:innen

HEPAUV-Cair cleanerbacteriophagebioaerosolpurification

Autor:innen und Institutionen

  • Health and Safety Executive Science and Research Centre, Buxton, United Kingdom.
  • The Animal & Plant Health Agency, Addlestone, United Kingdom.

ORCID-Profile: Claire Bailey

Zitieren

APA

Beswick, A., Brookes, J., Rosa, I., Bailey, C., Beynon, C., Stagg, S., & Bennett, N. (2023). Room-Based Assessment of Mobile Air Cleaning Devices Using a Bioaerosol Challenge. Applied Biosafety, 28(1), 1-10. https://doi.org/10.1089/apb.2022.0028

Vancouver

Beswick A, Brookes J, Rosa I, Bailey C, Beynon C, Stagg S, et al. Room-Based Assessment of Mobile Air Cleaning Devices Using a Bioaerosol Challenge. Applied Biosafety. 2023;28(1):1-10. doi:10.1089/apb.2022.0028

BibTeX
@article{Beswick2023,
  author = {Beswick, Alan and Brookes, Jodi and Rosa, Iwona and Bailey, Claire and Beynon, Charlotte and Stagg, Stephen and Bennett, Neil},
  title = {Room-Based Assessment of Mobile Air Cleaning Devices Using a Bioaerosol Challenge},
  journal = {Applied Biosafety},
  year = {2023},
  volume = {28},
  number = {1},
  pages = {1--10},
  doi = {10.1089/apb.2022.0028}
}
Kostenlos starten →