EUVIMEDEUVIMED entdecken
Open Access

The Evaluation and Exploration of Piezoelectric Parameter Optimization for Droplet Ejection in Binder Jet 3D Printing Drugs

Shanshan Wang iD, Xiaolu Han, Xiang Gao, Hui Zhang, Conghui Li, Shuwei Duan, Jie Wu, Zengming Wang, Aiping Zheng

3D Printing and Additive Manufacturing · 01.10.2023 · 10 (5) · 1090-1100

DOI: 10.1089/3dp.2022.0131 ↗

Kurz gefasst

Fachartikel in der Zeitschrift 3D Printing and Additive Manufacturing, online erschienen am 10.10.2023. Verfasst von Shanshan Wang und 8 weiteren Autor:innen. Beteiligte Einrichtung: College of Biotechnology, Tianjin University of Science and Technology, Tianjin, China. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Since the first three-dimensional (3D) printed drug was approved by the Food and Drug Administration in 2015, there has been a growing interest in using binder jet 3D printing (BJ-3DP) technology for pharmaceuticals. However, most studies are still at an exploratory stage, lacking micromechanism research, such as the droplet ejection mechanism, the effect of printhead piezoelectric parameters on inkjet smoothness and preparation formability. In this study, based on the inkjet printing and observation platform, the Epson I3200-A1 piezoelectric printhead matched to the self-developed BJ-3DP was selected to analyze the droplet ejection state of self-developed ink at the microlevel with different piezoelectric pulse parameters. The results showed that there was a stable inkjet state with an inkjet pulse width of 3.5 μs, an ink supply pulse width of 4.5 μs, and a jet frequency in the range of 5000–19,000 Hz, ensuring both better droplet pattern and print accuracy, as well as high ejection efficiency. In conclusion, we performed a systematic evaluation of the inkjet behavior under different piezoelectric pulse parameters and provided a good idea and case study for the optimization of printhead piezoelectric parameters when BJ-3DP technology was used in pharmaceuticals.

Schlagwörter

Stichwörter der Autor:innen

3D printed drugsbinder jet 3D printingdroplet ejection and observationpiezoelectric printheadpiezoelectric pulse parameters

Autor:innen und Institutionen

  • College of Biotechnology, Tianjin University of Science and Technology, Tianjin, China.
  • Pharmacy Research Laboratory, Institute of Pharmacology and Toxicology, Academy of Military Medical Sciences, Academy of Military Sciences, Beijing, China.
  • Department of Nephrology, First Medical Center of Chinese PLA General Hospital, National Clinical Research Center for Kidney Diseases, Beijing, China.

ORCID-Profile: Shanshan Wang

Zitieren

APA

Wang, S., Han, X., Gao, X., Zhang, H., Li, C., Duan, S., Wu, J., Wang, Z., & Zheng, A. (2023). The Evaluation and Exploration of Piezoelectric Parameter Optimization for Droplet Ejection in Binder Jet 3D Printing Drugs. 3D Printing and Additive Manufacturing, 10(5), 1090-1100. https://doi.org/10.1089/3dp.2022.0131

Vancouver

Wang S, Han X, Gao X, Zhang H, Li C, Duan S, et al. The Evaluation and Exploration of Piezoelectric Parameter Optimization for Droplet Ejection in Binder Jet 3D Printing Drugs. 3D Printing and Additive Manufacturing. 2023;10(5):1090-1100. doi:10.1089/3dp.2022.0131

BibTeX
@article{Wang2023,
  author = {Wang, Shanshan and Han, Xiaolu and Gao, Xiang and Zhang, Hui and Li, Conghui and Duan, Shuwei and Wu, Jie and Wang, Zengming and Zheng, Aiping},
  title = {The Evaluation and Exploration of Piezoelectric Parameter Optimization for Droplet Ejection in Binder Jet 3D Printing Drugs},
  journal = {3D Printing and Additive Manufacturing},
  year = {2023},
  volume = {10},
  number = {5},
  pages = {1090--1100},
  doi = {10.1089/3dp.2022.0131}
}