Live Transmission of Neonatal Echocardiograms from Underserved Areas: Accuracy, Patient Care, and Cost

C Sable, T Roca, J Gold, A Gutierrez, E Gulotta, W Culpepper

Telemedicine Journal · 1999

DOI: 10.1089/107830299311907 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Telemedicine Journal, 1999. Verfasst von C Sable und 5 weiteren Autor:innen. Beteiligte Einrichtung: Children's National Medical Center, Washington, DC, USA. Hauptthemen laut MEDLINE: Medically Underserved Area, Remote Consultation. Die Arbeit wurde bisher 50-mal zitiert (Crossref) und nennt 16 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: Echocardiography is an important tool in the diagnosis and management of critically ill neonates. The authors hypothesized that live telemedicine guidance and interpretation of neonatal echocardiograms from underserved areas would improve management, prevent unnecessary transports, enhance sonographer proficiency, and result in monetary savings. MATERIALS AND METHODS: Using personal computers capable of real-time transmission of echocardiograms over three integrated services digital network (ISDN) telephone lines, pediatric cardiologists interpreted echocardiograms, suggested views to sonographers, and made recommendations to neonatologists 200 miles away. Analyses of accuracy, management, echocardiogram quality, time, and costs were carried out prospectively. RESULTS: Sixty studies were transmitted over 7 months. Indications for echocardiography were suspected congenital heart disease (n = 29), suspected patent ductus arteriosus (PDA) (n = 27), and hemodynamic instability (n = 4). Diagnoses were critical congenital heart disease (n = 4), noncritical heart disease (n = 8), PDA (n = 21), ventricular dysfunction (n = 5), persistent pulmonary hypertension (n = 3), and normal (n = 19). Videotape review confirmed all telemedicine interpretations. The echocardiogram led to immediate change in management in 25 cases (42%), and echocardiogram quality was improved in 53 studies (88%). Time from request to completion of echocardiography was 43+/-30 min. Monetary savings from five avoided transports exceeded all expenses. CONCLUSION: Live transmission of neonatal echocardiograms over three ISDN lines is diagnostic, improves patient care and echocardiography quality, and is cost effective.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Medically Underserved AreaRemote ConsultationDuctus Arteriosus, PatentEchocardiographyHeart Defects, CongenitalHumansInfant, NewbornLouisianaVideotape Recording

Autor:innen und Institutionen

  • Children's National Medical Center, Washington, DC, USA.

Zitieren

APA

Sable, C., Roca, T., Gold, J., Gutierrez, A., Gulotta, E., & Culpepper, W. (1999). Live Transmission of Neonatal Echocardiograms from Underserved Areas: Accuracy, Patient Care, and Cost. Telemedicine Journal. https://doi.org/10.1089/107830299311907

Vancouver

Sable C, Roca T, Gold J, Gutierrez A, Gulotta E, Culpepper W. Live Transmission of Neonatal Echocardiograms from Underserved Areas: Accuracy, Patient Care, and Cost. Telemedicine Journal. 1999. doi:10.1089/107830299311907

BibTeX
@article{Sable1999,
  author = {Sable, C and Roca, T and Gold, J and Gutierrez, A and Gulotta, E and Culpepper, W},
  title = {Live Transmission of Neonatal Echocardiograms from Underserved Areas: Accuracy, Patient Care, and Cost},
  journal = {Telemedicine Journal},
  year = {1999},
  doi = {10.1089/107830299311907}
}
Kostenlos starten →