EUVIMEDEUVIMED entdecken
Crossref

Simulation research on temperature rise of composite vacuum interrupter

Limin Chen, Liang Liu, Heqing Shen, Jian Li, Jingjing Du, Zhongjia Song, Huajun Dong

Engineering Research Express · 01.07.2026 · 8 (13) · 135348

DOI: 10.1088/2631-8695/ae85cf ↗

Kurz gefasst

Fachartikel in der Zeitschrift Engineering Research Express, online erschienen am 08.07.2026. Verfasst von Limin Chen und 6 weiteren Autor:innen. Die Arbeit nennt 25 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Vacuum interrupters with composite transverse magnetic field (TMF) and axial magnetic field (AMF) contacts have attracted increasing attention because of their potential advantages in arc control and current-carrying performance. However, the temperature-rise behavior, heat-source distribution, and influence mechanism of key structural parameters in composite TMF-AMF contact vacuum interrupters have not been sufficiently clarified. To address this issue, a three-dimensional bidirectional electromagnetic–thermal coupled simulation model is established in this study. The eddy-current field is solved in Maxwell under rated current conditions, and the calculated Ohmic loss is then transferred to the steady-state thermal solver as the volumetric Joule heat source. Based on this model, the effects of contact force, TMF contact diameter, conducting rod diameter, contact material, envelope material, and external convective heat-transfer coefficient on the temperature field are investigated. The results show that the maximum temperature occurs near the conductive bridge at the contact interface, where current constriction causes concentrated Ohmic loss. Increasing the contact force, TMF contact diameter, and conducting rod diameter can effectively reduce the maximum temperature, but the cooling effect gradually weakens beyond certain parameter ranges. Material comparison indicates that the electrical and thermal conductivities of contact materials jointly determine the temperature-rise level. In addition, a ceramic envelope provides better heat-transfer performance than a glass envelope, and increasing the external convective heat-transfer coefficient reduces the peak temperature with diminishing returns. This study clarifies the electromagnetic–thermal coupling mechanism of composite TMF-AMF contact vacuum interrupters and provides simulation support for temperature-rise control and structural design.

Zitieren

APA

Chen, L., Liu, L., Shen, H., Li, J., Du, J., Song, Z., & Dong, H. (2026). Simulation research on temperature rise of composite vacuum interrupter. Engineering Research Express, 8(13), 135348. https://doi.org/10.1088/2631-8695/ae85cf

Vancouver

Chen L, Liu L, Shen H, Li J, Du J, Song Z, et al. Simulation research on temperature rise of composite vacuum interrupter. Engineering Research Express. 2026;8(13):135348. doi:10.1088/2631-8695/ae85cf

BibTeX
@article{Chen2026,
  author = {Chen, Limin and Liu, Liang and Shen, Heqing and Li, Jian and Du, Jingjing and Song, Zhongjia and Dong, Huajun},
  title = {Simulation research on temperature rise of composite vacuum interrupter},
  journal = {Engineering Research Express},
  year = {2026},
  volume = {8},
  number = {13},
  pages = {135348},
  doi = {10.1088/2631-8695/ae85cf}
}
Kostenlos starten →