EUVIMEDEUVIMED entdecken
Crossref

Analysis of the impact of insulation section damage in 25Hz phase-sensitive track circuits on the performance of adjacent track circuits

Bin Zhao, Jia Wang, Chengcai Fu, Xuejiao Jing

Engineering Research Express · 01.05.2026 · 8 (9) · 095309

DOI: 10.1088/2631-8695/ae62cd ↗

Kurz gefasst

Fachartikel in der Zeitschrift Engineering Research Express, online erschienen am 30.04.2026. Verfasst von Bin Zhao und 3 weiteren Autor:innen. Die Arbeit nennt 26 Literaturangaben. Gefördert von: National Natural Science Foundation of China Grant-in-Aid Project.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper addresses the impact of mechanical insulation joint damage on the performance of adjacent track circuits in 25 Hz phase-sensitive track circuits. A mathematical model of insulation joint damage is established to quantitatively analyze the correlation between damage severity and track circuit electrical parameters. First, based on mesh analysis and the superposition theorem, an equivalent four-terminal network model of the track circuits on both sides of the insulating joint is constructed, and analytical expressions for the voltage and current at the receiving end after damage are derived. Second, the parameters of the four-terminal network and the input impedances at the power supply and receiving ends are determined. Finally, simulation calculations analyze the influence patterns of single-side and double-side insulating joint damage on the power supply and receiving ends of the track circuit. The research findings indicate:—for single-side damage, an insulation section impedance below 1.7 Ω triggers abrupt changes in electrical parameters, with critical threshold points of 29.15 Ω for current and 24.20 Ω for voltage amplitude variation; bilateral damage exhibits a nonlinear superposition effect. When both-side impedances fall below 1 Ω, the receiving-end current drops from 0.8231 A to 0.2–0.3 A, and the voltage decreases from 0.45 V to 0.03 V. A parameter-sensitive region exists within the 0.1–10 Ω impedance range. The analytical model established and impedance thresholds determined in this paper provide a theoretical basis for quantifying the health status of insulating sections and enabling fault early warning.

Förderung

  • National Natural Science Foundation of China Grant-in-Aid Project

Zitieren

APA

Zhao, B., Wang, J., Fu, C., & Jing, X. (2026). Analysis of the impact of insulation section damage in 25Hz phase-sensitive track circuits on the performance of adjacent track circuits. Engineering Research Express, 8(9), 095309. https://doi.org/10.1088/2631-8695/ae62cd

Vancouver

Zhao B, Wang J, Fu C, Jing X. Analysis of the impact of insulation section damage in 25Hz phase-sensitive track circuits on the performance of adjacent track circuits. Engineering Research Express. 2026;8(9):095309. doi:10.1088/2631-8695/ae62cd

BibTeX
@article{Zhao2026,
  author = {Zhao, Bin and Wang, Jia and Fu, Chengcai and Jing, Xuejiao},
  title = {Analysis of the impact of insulation section damage in 25Hz phase-sensitive track circuits on the performance of adjacent track circuits},
  journal = {Engineering Research Express},
  year = {2026},
  volume = {8},
  number = {9},
  pages = {095309},
  doi = {10.1088/2631-8695/ae62cd}
}
Kostenlos starten →