Study on structural integrity evaluation of composite automated ropeway system inspection manipulator using flexible multibody dynamics
Functional Composites and Structures · 01.06.2026 · 8 (2) · 025004
DOI: 10.1088/2631-6331/ae5cf6 ↗Kurz gefasst
Fachartikel in der Zeitschrift Functional Composites and Structures, online erschienen am 28.04.2026. Verfasst von Chi Hyun Song und 4 weiteren Autor:innen. Die Arbeit nennt 13 Literaturangaben. Gefördert von: Korea Evaluation Institute of Industrial Technology.
Abstract (Originalsprache)
This study presents the structural design and structural integrity evaluation of carbon fiber reinforced plastic(CFRP) link arms applied on a ropeway structure inspection manipulator. The ropeway structure inspection manipulator is a device that remotely inspects defects and wear of ropeway wheel devices of rope facilities used as transportation, such as cable cars or ski lifts. Conventional inspection of ropeway wheel assemblies has relied on on-site visual checks by personnel at elevated locations, which poses safety risks and limits measurement consistency. In contrast, a ropeway inspection manipulator system is being developed domestically to enhance inspector safety and enable precise measurements using a laser scanner and camera mounted on the end device. To enhance the stiffness of the manipulator links and achieve a lightweight design, CFRP was adopted. To confirm the applicability of a composite manipulator to ropeway system inspection, the laminate stacking pattern was treated as a design variable and a deflection analysis of the composite link arms was performed. For the motion reflected in the analysis, the maximum deflection of the end device equipped with the camera was confirmed in the motion state where the inspection manipulator, which occurred to have the maximum deflection, was horizontally spread out. Based on the deflection analysis, we selected a stacking pattern which reduced deflection about 72.13% relative to the baseline model. Structural integrity was evaluated using a flexible multibody dynamics (FMBD) model that incorporated the selected layup pattern under the actual ropeway wheel inspection motion. For the failure evaluation of the composite materials, the Tsai–Wu failure criterion was adopted. As the results, the maximum Tsai–Wu index was 0.08, in the link arms were less than 1, confirming structural integrity.
Förderung
- Korea Evaluation Institute of Industrial Technology
Zitieren
APA
Song, C. H., Kim, C. H., Jeon, Y. H., Lee, J. Y., & Shin, K. B. (2026). Study on structural integrity evaluation of composite automated ropeway system inspection manipulator using flexible multibody dynamics. Functional Composites and Structures, 8(2), 025004. https://doi.org/10.1088/2631-6331/ae5cf6
Vancouver
Song CH, Kim CH, Jeon YH, Lee JY, Shin KB. Study on structural integrity evaluation of composite automated ropeway system inspection manipulator using flexible multibody dynamics. Functional Composites and Structures. 2026;8(2):025004. doi:10.1088/2631-6331/ae5cf6
BibTeX
@article{Song2026,
author = {Song, Chi Hyun and Kim, Chang Ho and Jeon, Yeong Hwan and Lee, Jae Youl and Shin, Kwang Bok},
title = {Study on structural integrity evaluation of composite automated ropeway system inspection manipulator using flexible multibody dynamics},
journal = {Functional Composites and Structures},
year = {2026},
volume = {8},
number = {2},
pages = {025004},
doi = {10.1088/2631-6331/ae5cf6}
}
EUVIMED