Study on the influence of cathode position on the performance of a low-power magnetically enhanced hollow cathode thruster
Plasma Science and Technology · 19.11.2026
DOI: 10.1088/2058-6272/aec41e ↗Kurz gefasst
Fachartikel in der Zeitschrift Plasma Science and Technology, online erschienen am 19.11.2026. Verfasst von Dongyang Zhang und 2 weiteren Autor:innen. Gefördert von: Aerospace Power Fund of the China Aerospace Foundation.
Abstract (Originalsprache)
To investigate the influence of cathode position on the discharge characteristics, plume characteristics, and propulsion performance of a low-power magnetically enhanced hollow cathode thruster (MHCT), comparative experiments were conducted using center-mounted and externally mounted cathode configurations under different anode voltages and xenon flow rates. The anode current, discharge oscillations, plume ion current density, ion energy distribution, thrust, specific impulse, and thrust efficiency were measured and analyzed. The results show that the center-mounted cathode configuration generally exhibited a higher anode current and could maintain stable discharge at lower anode voltages under low-flow-rate conditions. Compared with the externally mounted cathode configuration, the center-mounted cathode exhibited a higher dominant discharge oscillation frequency and weaker harmonic components. At a total xenon flow rate of 4 sccm, the mass utilization efficiency of the center-mounted cathode configuration reached approximately 58.5%–59.7%, compared with 29.4%–46.4% for the externally mounted cathode configuration. Although the externally mounted cathode produced a higher peak ion current density near the thruster axis and a more concentrated ion beam, the center-mounted cathode generally generated a higher total plume ion current. Retarding potential analyzer measurements at 280 V and 4 sccm revealed relatively low ion energies along the thruster axis for both configurations, with higher ion energies observed in the off-axis regions. The center-mounted cathode configuration generally achieved higher thrust, specific impulse, and thrust efficiency, particularly under low-flow-rate conditions. These results indicate that cathode position affects the coupling between the cathode and the main discharge region, as well as ion production and acceleration, thereby influencing the overall propulsion performance of the MHCT.
Förderung
- Aerospace Power Fund of the China Aerospace Foundation
Zitieren
APA
Zhang, D., Ning, Z., & Wang, Y. (2026). Study on the influence of cathode position on the performance of a low-power magnetically enhanced hollow cathode thruster. Plasma Science and Technology. https://doi.org/10.1088/2058-6272/aec41e
Vancouver
Zhang D, Ning Z, Wang Y. Study on the influence of cathode position on the performance of a low-power magnetically enhanced hollow cathode thruster. Plasma Science and Technology. 2026. doi:10.1088/2058-6272/aec41e
BibTeX
@article{Zhang2026,
author = {Zhang, Dongyang and Ning, Zhongxi and Wang, Yue},
title = {Study on the influence of cathode position on the performance of a low-power magnetically enhanced hollow cathode thruster},
journal = {Plasma Science and Technology},
year = {2026},
doi = {10.1088/2058-6272/aec41e}
}
EUVIMED