EUVIMEDEUVIMED entdecken
Crossref

A Compact Eight-Parameter Analytical Model of Photon-Beam Lateral Dose Profiles: Plateau, Penumbra and Out-of-Field Tail Decomposition for Elekta Linear Accelerators

Mustapha Zerfaoui iD, Ibrahim Ait Ouaggou iD, Mohammed Rezzoug iD, Omar Hamzaoui, Yassine Oulhouq iD, Samir Didi iD, Abdeslem Rrhioua iD, Dikra Bakari, Hassan Ou Hadda iD

Biomedical Physics & Engineering Express · 17.11.2026

DOI: 10.1088/2057-1976/aec2f0 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Physics & Engineering Express, online erschienen am 17.11.2026. Verfasst von Mustapha Zerfaoui und 8 weiteren Autor:innen. Beteiligte Einrichtung: physique, Laboratory of Physics of Matter and Radiation Faculty of Sciences, Mohammed first University Oujda, Morocco, UMP, Oujda, 60000, Morocco.

AbstractSchlagwörterBibliografische AngabenZitieren

Abstract (Originalsprache)

To develop and validate a compact analytical model of megavoltage photon-beam lateral dose profiles, with eight physically interpretable parameters per profile, for beam-data quality assurance (QA) and treatment planning system (TPS) commissioning support. The relative dose at off-axis position x, for a field of half-width R, is expressed as D(x,R) = A·F(x,R)·P(x,R) + S(x,R), where F (a fourth-order polynomial in x/R) describes the plateau, P (an error-function pair of width σ) the penumbra, and S (an exponential) the out-of-field tail. The parameters were fitted to 58 in-plane profiles measured on an Elekta linac at 6, 10 and 15 MV (1×1 to 40×40 cm², depths 1.5–20 cm), and the model was tested on 14 independent profiles (second linac, Monte Carlo). Agreement was assessed with the root-mean-square error (RMSE), R² and the global gamma index at 2%/2 mm and 1%/1 mm. All profiles passed 2%/2 mm at 100%, with a mean RMSE of 0.551% (range 0.24–1.19%) and R² ≥ 0.9978; the independent profiles gave a mean RMSE of 0.541%. At 1%/1 mm, 99.2% of points passed, and all 6 MV profiles and all fields ≥ 4×4 cm² passed at ≥ 95%; the remaining deviations were confined to small 10–15 MV fields and low-gradient regions. The parameters followed physically consistent trends: σ increased with depth and, for fields ≥ 5×5 cm², with energy, B increased with depth and with field size up to 30×30 cm², α decreased with depth, and H and H₄ tracked the loss of horns with depth. Each parameter retains a direct physical meaning, and the parameters recovered simulated jaw-calibration and steering errors set at or below the AAPM TG-142 tolerances, supporting their use in beam-data QA and commissioning; independent dose calculation will require a continuous parameterization in depth and field size.

Schlagwörter

Stichwörter der Autor:innen

beam commissioninglateral dose profilephoton beam dosimetryrelative dosimetrysemi-empirical model

Autor:innen und Institutionen

  • physique, Laboratory of Physics of Matter and Radiation Faculty of Sciences, Mohammed first University Oujda, Morocco, UMP, Oujda, 60000, Morocco.
  • Mohammed First University Oujda, ibrahim.aitouaggou@ump.ac.ma, Oujda, 60000, Morocco.
  • Radiotherapy, Mohammed VI University Hospital Oujda, nmedrezz@gmail.com, Oujda, 60049, Morocco.
  • Computer Science and Oncology, University Mohamed 1st, oujda, oujda, 60000, Morocco.
  • Mohammed I University Oujda, ump, Oujda, Oriental, 60000, Morocco.
  • Department de physics, Université Mohammed Premier Oujda Faculté Pluridisciplinaire de Nador, Faculté Pluridisciplinaire de Nador, B.P 300, Selouane, 62700 - 62700, Selouane, Oujda, 62700, Morocco.

ORCID-Profile: Mustapha Zerfaoui, Ibrahim Ait Ouaggou, Mohammed Rezzoug, Yassine Oulhouq, Samir Didi, Abdeslem Rrhioua, Hassan Ou Hadda

Zitieren

APA

Zerfaoui, M., Ait Ouaggou, I., Rezzoug, M., Hamzaoui, O., Oulhouq, Y., Didi, S., Rrhioua, A., Bakari, D., & Ou Hadda, H. (2026). A Compact Eight-Parameter Analytical Model of Photon-Beam Lateral Dose Profiles: Plateau, Penumbra and Out-of-Field Tail Decomposition for Elekta Linear Accelerators. Biomedical Physics & Engineering Express. https://doi.org/10.1088/2057-1976/aec2f0

Vancouver

Zerfaoui M, Ait Ouaggou I, Rezzoug M, Hamzaoui O, Oulhouq Y, Didi S, et al. A Compact Eight-Parameter Analytical Model of Photon-Beam Lateral Dose Profiles: Plateau, Penumbra and Out-of-Field Tail Decomposition for Elekta Linear Accelerators. Biomedical Physics & Engineering Express. 2026. doi:10.1088/2057-1976/aec2f0

BibTeX
@article{Zerfaoui2026,
  author = {Zerfaoui, Mustapha and Ait Ouaggou, Ibrahim and Rezzoug, Mohammed and Hamzaoui, Omar and Oulhouq, Yassine and Didi, Samir and Rrhioua, Abdeslem and Bakari, Dikra and Ou Hadda, Hassan},
  title = {A Compact Eight-Parameter Analytical Model of Photon-Beam Lateral Dose Profiles: Plateau, Penumbra and Out-of-Field Tail Decomposition for Elekta Linear Accelerators},
  journal = {Biomedical Physics & Engineering Express},
  year = {2026},
  doi = {10.1088/2057-1976/aec2f0}
}
Kostenlos starten →