Fachartikel in der Zeitschrift Biomedical Physics & Engineering Express, online erschienen am 29.10.2026. Verfasst von Xiao Li und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Mechanical and Electrical Engineering, Lanzhou University of Technology, Lanzhou 730050, People's Republic of China. Hauptthemen laut MEDLINE: Liver, High-Intensity Focused Ultrasound Ablation, Liver Neoplasms, Blood Vessels. Die Arbeit nennt 20 Literaturangaben. Gefördert von: Lanzhou University of Technology Hongliu Outstanding Young Talent Support Program.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To evaluate the thermal safety and lesion conformity of low-duty-cycle pulsed ultrasound in an ex vivo liver model adjacent to large vessels. Impact Statement. This study evaluates a low-duty-cycle pulsed ultrasound strategy that may reduce dependence on thermal dose accumulation while preserving visible vessel-like structures under controlled ex vivo non-perfused conditions.

Introduction

Conventional thermal ablation for hepatocellular carcinoma is limited by the ‘heat sink effect,’ causing marginal residual tumors and risking irreversible damage to major blood vessels. Quantitative investigations defining the thermal safety boundaries of histotripsy to overcome these limitations are currently lacking.

Methods

Combining simulation optimization and ex-vivo validation, an acoustic-thermal coupled model identified an optimal protocol (2.0 MHz, 37 MPa, 0.5% duty cycle (DC)). Ex-vivo porcine liver experiments compared this cavitation ablation head-to-head with continuous-wave thermal ablation near major vessels, assessing morphology, conformity index (CI), and vascular integrity. The ex vivo model lacked active vascular perfusion, this study did not directly reproduce in vivo convective heat-sink conditions. The vessel-adjacent model was used to evaluate lesion formation and vessel-wall structural preservation under controlled non-perfused conditions.

Results

Simulations showed a 0.5% DC kept peak temperatures below the 60 °C denaturation threshold. Ex-vivo , the cavitation group achieved homogeneous liquefaction, sharp boundaries, and preserved adjacent vessels, yielding an approximate geometric CI of 96.8 ± 2.1%. The thermal group showed more irregular lesion morphology and lower geometric conformity under the tested ex vivo conditions, showing irregular defects and a lower CI of 71.2 ± 15.6% ( P < 0.01).

Conclusion

These findings support the feasibility of low-duty-cycle pulsed ultrasound as a non-thermal ablation strategy near vessel-like structures in ex vivo liver tissue, but its ability to mitigate heat-sink effects requires validation in perfused and in vivo models.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

LiverHigh-Intensity Focused Ultrasound AblationLiver NeoplasmsBlood VesselsCarcinoma, HepatocellularAnimalsHot TemperatureComputer Simulation

Stichwörter der Autor:innen

conformity indexheat sink effecthistotripsymedical roboticsnon-thermal ablationultrasound cavitation

Autor:innen und Institutionen

  • School of Mechanical and Electrical Engineering, Lanzhou University of Technology, Lanzhou 730050, People's Republic of China.

ORCID-Profile: Xiao Li, Ke Wu, YaKun Yan

Förderung

  • Lanzhou University of Technology Hongliu Outstanding Young Talent Support Program

Zitieren

APA

Li, X., Wu, K., Shen, Z., Yan, Y., Meng, W., Yang, D., & Duan, H. (2026). Low-duty-cycle pulsed ultrasound for ex vivo liver tissue ablation: thermal safety, lesion conformity, and vascular structure preservation. Biomedical Physics & Engineering Express, 12(5), 055074. https://doi.org/10.1088/2057-1976/aeb425

Vancouver

Li X, Wu K, Shen Z, Yan Y, Meng W, Yang D, et al. Low-duty-cycle pulsed ultrasound for ex vivo liver tissue ablation: thermal safety, lesion conformity, and vascular structure preservation. Biomedical Physics & Engineering Express. 2026;12(5):055074. doi:10.1088/2057-1976/aeb425

BibTeX
@article{Li2026,
  author = {Li, Xiao and Wu, Ke and Shen, ZhenXin and Yan, YaKun and Meng, WeiHong and Yang, DongYa and Duan, HongYan},
  title = {Low-duty-cycle pulsed ultrasound for ex vivo liver tissue ablation: thermal safety, lesion conformity, and vascular structure preservation},
  journal = {Biomedical Physics & Engineering Express},
  year = {2026},
  volume = {12},
  number = {5},
  pages = {055074},
  doi = {10.1088/2057-1976/aeb425}
}
Kostenlos starten →