Reliability and reproducibility of piezoelectric-derived local brachial pulse wave velocity measurement and pressure normalization
Biomedical Physics & Engineering Express · 01.08.2026 · 12 (4) · 045012
DOI: 10.1088/2057-1976/ae83bc ↗Kurz gefasst
Fachartikel in der Zeitschrift Biomedical Physics & Engineering Express, online erschienen am 08.07.2026. Verfasst von Nimmi Sudarsan und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical Engineering, Indian Institute of Technology Madras, Chennai 600 036, India. Hauptthemen laut MEDLINE: Pulse Wave Analysis, Brachial Artery, Blood Pressure, Vascular Stiffness. Die Arbeit nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Department of Higher Education, India, Science and Engineering Research Board.
Abstract (Originalsprache)
Background
Local pulse wave velocity (PWV) is an emerging non-invasive marker of arterial stiffness that enables site-specific evaluation of vascular health and early detection of localized vessel stiffening associated with cardiovascular risk.
Methods
In this study, local brachial PWV was measured using two piezoelectric sensors placed proximally and distally along the brachial artery to determine intra- and inter-rater reliability and compare the results with standard ultrasound-derived PWV. The brachial artery was chosen for its accessibility, consistent geometry, and physiological relevance as a peripheral muscular artery sensitive to early vascular changes. Thirty-five healthy participants (17 M:18 F) underwent local brachial PWV measurements in a controlled environment. Measurements were repeated within the same day (intra- and inter-rater), across different days, and at a six-month follow-up to evaluate temporal reproducibility. Additionally, blood pressure was estimated from the piezoelectric pulse signals, and PWV was normalized to mean arterial pressure (MAP) to examine whether normalization improved repeatability.
Results
Intra-rater reliability was excellent (ICC = 0.94 [0.91–0.97], CV = 3.0%), while inter-rater reliability was good (ICC = 0.82 [0.76–0.87], CV = 6.0%). Between-day reproducibility remained high (ICC = 0.87 [0.82–0.91]). PWV correlated strongly with ultrasound-derived PWV ( R 2 = 0.79, p < 0.001). Measurements at six-month follow-up demonstrated good temporal reproducibility (ICC = 0.71 [0.67–0.79]). Normalization of PWV to MAP reduced measurement variability.
Conclusion
Local brachial PWV measurements exhibit high reliability, strong agreement with ultrasound PWV, and consistent temporal reproducibility, particularly when normalized to MAP. These findings support the methodological validity and reproducibility of local brachial PWV assessment and provide a foundation for future standardization and clinical evaluation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Electrical Engineering, Indian Institute of Technology Madras, Chennai 600 036, India.
- Healthcare Technology Innovation Centre, Indian Institute of Technology Madras, Chennai 600 036, India.
- Department of Physiology, All India Institute of Medical Sciences, New Delhi 110 029, India.
ORCID-Profile: Nimmi Sudarsan
Förderung
- Department of Higher Education, India
- Science and Engineering Research Board
Zitieren
APA
Sudarsan, N., Nabeel, P. M., Raj, K. V., Chandran, D. S., & Joseph, J. (2026). Reliability and reproducibility of piezoelectric-derived local brachial pulse wave velocity measurement and pressure normalization. Biomedical Physics & Engineering Express, 12(4), 045012. https://doi.org/10.1088/2057-1976/ae83bc
Vancouver
Sudarsan N, Nabeel PM, Raj KV, Chandran DS, Joseph J. Reliability and reproducibility of piezoelectric-derived local brachial pulse wave velocity measurement and pressure normalization. Biomedical Physics & Engineering Express. 2026;12(4):045012. doi:10.1088/2057-1976/ae83bc
BibTeX
@article{Sudarsan2026,
author = {Sudarsan, Nimmi and Nabeel, P M and Raj, Kiran V and Chandran, Dinu S and Joseph, Jayaraj},
title = {Reliability and reproducibility of piezoelectric-derived local brachial pulse wave velocity measurement and pressure normalization},
journal = {Biomedical Physics & Engineering Express},
year = {2026},
volume = {12},
number = {4},
pages = {045012},
doi = {10.1088/2057-1976/ae83bc}
}