A dual stage wavelet workflow for motion artifact localization and correction in reflected light fNIRS signals
Biomedical Physics & Engineering Express · 01.06.2026 · 12 (3) · 035056
DOI: 10.1088/2057-1976/ae71d5 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biomedical Physics & Engineering Express, online erschienen am 02.06.2026. Verfasst von Cinthya L Toledo-Peral und 7 weiteren Autor:innen. Beteiligte Einrichtung: Division for Research in Medical Engineering, Instituto Nacional de Rehabilitación Luis Guillermo Ibarra Ibarra, Mexico City, Mexico. Hauptthemen laut MEDLINE: Artifacts, Wavelet Analysis, Signal Processing, Computer-Assisted. Die Arbeit nennt 26 Literaturangaben.
Abstract (Originalsprache)
Motion artifacts in functional near-infrared spectroscopy (fNIRS) signals can distort reflected light waveforms and affect derived physiological estimates. This study presents a dual stage, joint ROI guided wavelet workflow for motion artifact localization and correction in reflected light fNIRS signals from the PhysioNet database Motion Artifact Contaminated fNIRS and EEG Data . The method combines continuous wavelet transform based joint ROI detection across the 690 and 830 nm signals with local dual threshold discrete wavelet correction and smooth boundary blending. Performance was assessed by mean squared error (MSE) within artifact contaminated ROIs and by root mean square error (RMSE) of a ratio based oxygen saturation estimate relative to the clean reference channel. Compared with spline-Savitzky–Golay and global dual threshold wavelet benchmarks, the proposed workflow achieved the lowest estimate domain RMSE in five of nine trials. These findings support joint ROI guided local wavelet correction as a competitive strategy for preserving ratio derived reflected light estimates in this dataset.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division for Research in Medical Engineering, Instituto Nacional de Rehabilitación Luis Guillermo Ibarra Ibarra, Mexico City, Mexico.
- La Salle University, Mexico City, Mexico.
- Bioelectronics Section, Centro de Investigación y de Estudios Avanzados del IPN, Mexico City, Mexico.
- Sección de Estudios de Posgrado e Investigación, Escuela Superior de Medicina, Instituto Politécnico Nacional, Mexico City, Mexico.
ORCID-Profile: Cinthya L Toledo-Peral, Gabriel Vega-Martínez, Ximena Romero-Gómez, Jesús Fausto Córdova-Manzo, Jorge Airy Mercado-Gutierrez, Arturo Vera-Hernández, Israel Ramírez-Sánchez, Sonia Patricia Romano-Riquer
Zitieren
APA
Toledo-Peral, C. L., Vega-Martínez, G., Romero-Gómez, X., Córdova-Manzo, J. F., Mercado-Gutierrez, J. A., Vera-Hernández, A., Ramírez-Sánchez, I., & Romano-Riquer, S. P. (2026). A dual stage wavelet workflow for motion artifact localization and correction in reflected light fNIRS signals. Biomedical Physics & Engineering Express, 12(3), 035056. https://doi.org/10.1088/2057-1976/ae71d5
Vancouver
Toledo-Peral CL, Vega-Martínez G, Romero-Gómez X, Córdova-Manzo JF, Mercado-Gutierrez JA, Vera-Hernández A, et al. A dual stage wavelet workflow for motion artifact localization and correction in reflected light fNIRS signals. Biomedical Physics & Engineering Express. 2026;12(3):035056. doi:10.1088/2057-1976/ae71d5
BibTeX
@article{ToledoPeral2026,
author = {Toledo-Peral, Cinthya L and Vega-Martínez, Gabriel and Romero-Gómez, Ximena and Córdova-Manzo, Jesús Fausto and Mercado-Gutierrez, Jorge Airy and Vera-Hernández, Arturo and Ramírez-Sánchez, Israel and Romano-Riquer, Sonia Patricia},
title = {A dual stage wavelet workflow for motion artifact localization and correction in reflected light fNIRS signals},
journal = {Biomedical Physics & Engineering Express},
year = {2026},
volume = {12},
number = {3},
pages = {035056},
doi = {10.1088/2057-1976/ae71d5}
}
EUVIMED