Evaluating coagulation factor II deficiency using impulsive acoustic radiation force
Biomedical Physics & Engineering Express · 01.06.2026 · 12 (3) · 035033
DOI: 10.1088/2057-1976/ae6dc6 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biomedical Physics & Engineering Express, online erschienen am 22.05.2026. Verfasst von José Francisco Silva Costa-Júnior und 1 weiteren Autor:innen. Beteiligte Einrichtung: Postgraduate Program in Biomedical Engineering, Brazil University, Itaquera, SP, Brazil. Hauptthemen laut MEDLINE: Prothrombin. Die Arbeit nennt 28 Literaturangaben. Gefördert von: Fundação Carlos Chagas Filho de Amparo à Pesquisa do Estado do Rio de Janeiro, Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, Conselho Nacional de Desenvolvimento Científico e Tecnológico.
Abstract (Originalsprache)
Impaired liver function, often caused by disease or anticoagulant therapy, can result in deficiencies of essential coagulation factors, including clotting Factor II. This underscores the importance of developing ultrasonic systems capable of detecting clotting factor deficiencies in plasma sample. This study explored the potential of an impulsive acoustic radiation force (IARF)-based ultrasonic system to assess plasma stiffness and distinguish between normal plasma and plasma deficient in coagulation Factor II. The system employed focused ultrasonic beams on a solid sphere, inducing microdisplacement when immersed in human plasma samples. An electrical signal with a frequency of 2.03406 MHz, amplitude of 118 V PP , and pulse repetition frequency of 1.249 Hz powered the ultrasonic transducer. Microdisplacement was monitored using an SR-9000 board operating in pulse-echo mode at 4.89 MHz. Experimental and theoretical microdisplacement curves were used to determine the shear modulus ( μ ) and time-to-peak displacement (TPD) of plasma samples during coagulation. For control plasma and plasma deficient in coagulation Factor II, μ values measured between 10 and 35 min after coagulation onset were 300.11 ± 14.55 Pa and 75.53 ± 2.91 Pa, respectively. Under the same conditions, TPD ranged from 4.86 ± 0.28 ms to 6.97 ± 0.35 ms. A statistically significant difference in μ and TPD values was observed between normal and Factor II-deficient plasma samples. Furthermore, the μ time-curve of prothrombin-deficient plasma exhibited a distinct pattern. These findings demonstrate the potential of the IARF-based ultrasonic system as a laboratory-scale research tool capable of detecting viscoelastic changes in small plasma volumes. While promising, further validation, particularly with larger sample sizes, standardized activation protocols, and clinical cohorts, is required before its applicability to diagnosing coagulation disorders or monitoring therapies can be established.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Postgraduate Program in Biomedical Engineering, Brazil University, Itaquera, SP, Brazil.
- Biomedical Engineering Program, COPPE, Federal University of Rio de Janeiro, Rio de Janeiro, RJ, Brazil.
- Post-Graduation Program on Surgical Sciences-School of Medicine/Federal University of Rio de Janeiro, Rio de Janeiro, RJ, Brazil.
ORCID-Profile: José Francisco Silva Costa-Júnior
Förderung
- Fundação Carlos Chagas Filho de Amparo à Pesquisa do Estado do Rio de Janeiro
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
- Conselho Nacional de Desenvolvimento Científico e Tecnológico
Zitieren
APA
Costa-Júnior, J. F. S., & Machado, J. C. (2026). Evaluating coagulation factor II deficiency using impulsive acoustic radiation force. Biomedical Physics & Engineering Express, 12(3), 035033. https://doi.org/10.1088/2057-1976/ae6dc6
Vancouver
Costa-Júnior JFS, Machado JC. Evaluating coagulation factor II deficiency using impulsive acoustic radiation force. Biomedical Physics & Engineering Express. 2026;12(3):035033. doi:10.1088/2057-1976/ae6dc6
BibTeX
@article{CostaJnior2026,
author = {Costa-Júnior, José Francisco Silva and Machado, João Carlos},
title = {Evaluating coagulation factor II deficiency using impulsive acoustic radiation force},
journal = {Biomedical Physics & Engineering Express},
year = {2026},
volume = {12},
number = {3},
pages = {035033},
doi = {10.1088/2057-1976/ae6dc6}
}
EUVIMED