Synergistic effects of plaque geometry and composition on coronary hemodynamics and mechanical stability: a multiscale computational study
Biomedical Physics & Engineering Express · 01.06.2026 · 12 (3) · 035007
DOI: 10.1088/2057-1976/ae5fa0 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biomedical Physics & Engineering Express, online erschienen am 24.04.2026. Verfasst von Yinghong Zhao und 7 weiteren Autor:innen. Beteiligte Einrichtung: China University of Mining and Technology, No.1, Daxue Road, Xuzhou, Jiangsu, People's Republic of China. Hauptthemen laut MEDLINE: Plaque, Atherosclerotic, Hemodynamics, Computer Simulation, Coronary Vessels. Die Arbeit nennt 30 Literaturangaben. Gefördert von: of Innovation and Entrepreneurship for Undergraduates, Fundamental Research Funds for Science and Technology in Xuzhou.
Abstract (Originalsprache)
Cardiovascular disease remains the leading cause of global mortality, with the rupture of vulnerable atherosclerotic plaques accounting for the majority of acute myocardial infarctions. While plaque morphology and composition are well recognized as critical determinants of vulnerability, their combined effects across clinically relevant stenosis severities (50%–80%) remain incompletely understood. To address this gap, this study aimed to systematically investigate the collective influence of plaque geometry (eccentric vs. concentric) and material composition (lipid, fibrous, calcified) on coronary hemodynamics and mechanical plaque stability under identical stenosis conditions. The left anterior descending artery were reconstructed using clinical computed tomography angiography data, and key hemodynamic (wall shear stress [WSS], oscillatory shear index [OSI], relative residence time [RRT]) and structural metrics (plaque von Mises stress and deformation) were quantified via coupled computational fluid dynamics and fluid-structure interaction simulations. The results demonstrated that eccentric plaques induced significantly more pronounced asymmetric flow disturbances, steeper WSS gradients, and higher RRT values compared to concentric geometries, particularly at higher stenosis severities; notably, at 70% stenosis, the mean RRT of eccentric plaques (0.108 65) was nearly double that of concentric plaques (0.056 86), and eccentric plaques exhibited a unique low-oscillatory shear environment with upstream mean OSI reduced to 0.141 01, whereas concentric plaques showed upstream mean OSI elevated to 0.256 07. Compositionally, lipid-rich regions experienced the greatest deformation, highlighting their role as mechanical ‘weak spots,’ whereas calcified areas showed minimal deformation but generated interfacial stress concentrations. These findings elucidate the synergistic interaction between plaque geometry and composition in modulating coronary hemodynamics and mechanical integrity, with eccentric morphology exacerbating adverse biomechanical conditions as stenosis progresses. This study provides a novel, multiscale biomechanical framework for assessing plaque vulnerability and informs the development of personalized intervention strategies tailored to specific plaque characteristics.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- China University of Mining and Technology, No.1, Daxue Road, Xuzhou, Jiangsu, People's Republic of China.
- Xuzhou Medical University, No. 209 Tongshan Road, Xuzhou, Jiangsu, People's Republic of China.
- Department of Radiology, The First Affiliated Hospital of Anhui Medical University, No. 218, Jixi Road, Hefei, Anhui, People's Republic of China.
ORCID-Profile: Yinghong Zhao, Gang Hua
Förderung
- of Innovation and Entrepreneurship for Undergraduates
- Fundamental Research Funds for Science and Technology in Xuzhou
Zitieren
APA
Zhao, Y., Chen, A., Liu, H., Cao, H., Chen, J., Tang, H., Wang, H., & Hua, G. (2026). Synergistic effects of plaque geometry and composition on coronary hemodynamics and mechanical stability: a multiscale computational study. Biomedical Physics & Engineering Express, 12(3), 035007. https://doi.org/10.1088/2057-1976/ae5fa0
Vancouver
Zhao Y, Chen A, Liu H, Cao H, Chen J, Tang H, et al. Synergistic effects of plaque geometry and composition on coronary hemodynamics and mechanical stability: a multiscale computational study. Biomedical Physics & Engineering Express. 2026;12(3):035007. doi:10.1088/2057-1976/ae5fa0
BibTeX
@article{Zhao2026,
author = {Zhao, Yinghong and Chen, Aoxue and Liu, Han and Cao, Hang and Chen, Jiayi and Tang, Hui and Wang, Huihui and Hua, Gang},
title = {Synergistic effects of plaque geometry and composition on coronary hemodynamics and mechanical stability: a multiscale computational study},
journal = {Biomedical Physics & Engineering Express},
year = {2026},
volume = {12},
number = {3},
pages = {035007},
doi = {10.1088/2057-1976/ae5fa0}
}
EUVIMED