EUVIMEDEUVIMED entdecken
Crossref

Computational modeling of paresthesia generated by SCS using a percutaneous lead: a proof-of-concept theoretical model based on an arbitrary somatotopic distribution

Tom Le Tutour iD, Karim El Houari, Maxime Billot iD, Michel Rochette iD, Arnaud Germaneau, Philippe Rigoard

Biomedical Physics & Engineering Express · 01.04.2026 · 12 (2) · 027001

DOI: 10.1088/2057-1976/ae4df4 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Physics & Engineering Express, online erschienen am 16.03.2026. Verfasst von Tom Le Tutour und 5 weiteren Autor:innen. Beteiligte Einrichtung: Institut Pprime, UPR 3346, CNRS-Université de Poitiers-ISAE-ENSMA, Poitiers, France. Hauptthemen laut MEDLINE: Paresthesia, Computer Simulation, Spinal Cord Stimulation, Models, Neurological. Die Arbeit nennt 56 Literaturangaben. Gefördert von: Association Nationale Recherche Technologie.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives .Chronic pain affects over two billion people worldwide, significantly reducing quality of life and placing a substantial burden on healthcare systems and society. Neuropathic painoriginates from lesions of the central or peripheral nervous system. Despite pharmacological, surgical and paramedical management, many patients continue experiencing persistent pain. Epidural Spinal Cord Stimulation (SCS) has become an effective alternative treatment for neuropathic pain. That said, SCS efficacy is dependent on many parameters, including optimized spatial targeting based on paresthesia generated by chosen and tuned SCS. In this context, iterative programming designed to optimize targeting and pain relief puts a major burden on health-care professionals. The leveraging of FEM and other computational techniques would enhance understanding of SCS mechanisms, optimize parameter selection, and ultimately improve patient outcomes. Approach . In this work, we present parametrizable computational model that facilitates the study of computed paresthesia. This model used the typical workflow of two-step simulation often employed for electrical stimulation of neural structures. First, the electrical field generated within the spinal cord and its surroundings was computed using the Finite-Element Method (FEM). The effects this electric field had on axons were then assessed with Ordinary Differential Equations (ODEs). The geometry of this model was based on a section of the PAM50 template of the spinal cord and its surroundings. Somatotopy of the spinal cord is explicitly represented by the fiber’s trajectories. A β myelinated fibers of the dorsal columns and roots are modelled using the McIntyre-Richardson-Grill (MRG) double cable model. Main results. The computational model produced paresthesia maps which generally followed expected projections in terms of lead laterality and rostro-caudal placement in paresthesia. Some interesting effects of rostro-caudal lead placement ata vertebral level were also observed and will be discussed. Significance . The computed paresthesia maps, which can be directly correlated to felt or measured paresthesia maps, represent a step towards clinical validation of in silico computational models of SCS.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ParesthesiaComputer SimulationSpinal Cord StimulationModels, NeurologicalHumansSpinal CordFinite Element AnalysisNeuralgiaProof of Concept Study

Stichwörter der Autor:innen

computational modellingcomputational neurosciencesfinite-element methodspinal cord stimulation

Autor:innen und Institutionen

  • Institut Pprime, UPR 3346, CNRS-Université de Poitiers-ISAE-ENSMA, Poitiers, France.
  • Ansys France, Villeurbanne, France.
  • CHU de Poitiers, PRISMATICS Lab (Predictive Research in Spine/Neuromodulation Management and Thoracic Innovation/Cardiac Surgery), F-86000 Poitiers, France.
  • Université de Poitiers, Université François-Rabelais de Tours, CNRS, CeRCA, UMR 7295, F-86000 Poitiers, France.
  • CHU de Poitiers, service de neurochirurgie du rachis, chirurgie de la douleur et du handicap, F-86000, France.

ORCID-Profile: Tom Le Tutour, Maxime Billot, Michel Rochette

Förderung

  • Association Nationale Recherche Technologie

Zitieren

APA

Le Tutour, T., El Houari, K., Billot, M., Rochette, M., Germaneau, A., & Rigoard, P. (2026). Computational modeling of paresthesia generated by SCS using a percutaneous lead: a proof-of-concept theoretical model based on an arbitrary somatotopic distribution. Biomedical Physics & Engineering Express, 12(2), 027001. https://doi.org/10.1088/2057-1976/ae4df4

Vancouver

Le Tutour T, El Houari K, Billot M, Rochette M, Germaneau A, Rigoard P. Computational modeling of paresthesia generated by SCS using a percutaneous lead: a proof-of-concept theoretical model based on an arbitrary somatotopic distribution. Biomedical Physics & Engineering Express. 2026;12(2):027001. doi:10.1088/2057-1976/ae4df4

BibTeX
@article{LeTutour2026,
  author = {Le Tutour, Tom and El Houari, Karim and Billot, Maxime and Rochette, Michel and Germaneau, Arnaud and Rigoard, Philippe},
  title = {Computational modeling of paresthesia generated by SCS using a percutaneous lead: a proof-of-concept theoretical model based on an arbitrary somatotopic distribution},
  journal = {Biomedical Physics & Engineering Express},
  year = {2026},
  volume = {12},
  number = {2},
  pages = {027001},
  doi = {10.1088/2057-1976/ae4df4}
}
Kostenlos starten →