Assessment of equivalent uniform RBE-weighted dose in hypofractionated proton therapy for ocular melanoma
Biomedical Physics & Engineering Express · 2025
DOI: 10.1088/2057-1976/adea7d ↗Kurz gefasst
Fachartikel in der Zeitschrift Biomedical Physics & Engineering Express, 2025. Verfasst von Pavitra Ramesh und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, University of Washington, 1959 NE Pacific Street, Seattle, WA, 98004, United States of America. Hauptthemen laut MEDLINE: Proton Therapy, Melanoma, Relative Biological Effectiveness, Eye Neoplasms. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objective. The equivalent uniform RBE-weighted dose (EUD RBE ) is computed in a model problem for hypofractionated proton therapy for ocular melanoma, considering the depth and dose dependence of the relative biological effectiveness (RBE). Approach. The EUD RBE was developed to compare the integrated cell survival in radiotherapy modalities with nonuniform distributions of the RBE and the physical dose. Our simulations of the EUD RBE in hypofractionated proton radiotherapy are based on the linear quadratic (LQ) cell survival model from which the dose correction to the RBE can be evaluated using the theory of dual radiation action. This theory predicts that the higher LET radiation increases the linear component ( α ) of radiation damage, while the quadratic component ( β ) remains unchanged. The effect of depth dependence of the RBE was derived from a fit to experimental data across various spread-out Bragg peaks (SOBPs) and the distribution of the physical dose was considered uniform. Main results . There are two competing processes that affect the EUD RBE : first, the EUD RBE decreases as the fractional dose increases, and second, the EUD RBE increases with increasing the relative fraction of tumors treated with high RBE at the distal edge of Bragg peak. Our simulations show that the combined effect of these two processes predicts an increase of the EUD RBE by 9%–12% relative to the physical dose for the fractionation schedule 5 × 10 Gy (RBE) assuming a distal tumor margin of 5 mm. Significance . The increase in the RBE at the end of the proton range largely compensates for the decrease in the RBE for higher fractional proton doses, thus producing the EUD RBE that does not deviate substantially from the clinically used uniform value of RBE = 1.1. The EUD RBE will enable more optimized proton therapy plans and comparison with other modalities such as eye plaque brachytherapy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Oncology, University of Washington, 1959 NE Pacific Street, Seattle, WA, 98004, United States of America.
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, MA, 02114, United States of America.
ORCID-Profile: Pavitra Ramesh, Alexei V Trofimov, Alexei V Chvetsov
Zitieren
APA
Ramesh, P., Trofimov, A. V., Rengan, R., & Chvetsov, A. V. (2025). Assessment of equivalent uniform RBE-weighted dose in hypofractionated proton therapy for ocular melanoma. Biomedical Physics & Engineering Express. https://doi.org/10.1088/2057-1976/adea7d
Vancouver
Ramesh P, Trofimov AV, Rengan R, Chvetsov AV. Assessment of equivalent uniform RBE-weighted dose in hypofractionated proton therapy for ocular melanoma. Biomedical Physics & Engineering Express. 2025. doi:10.1088/2057-1976/adea7d
BibTeX
@article{Ramesh2025,
author = {Ramesh, Pavitra and Trofimov, Alexei V and Rengan, Ramesh and Chvetsov, Alexei V},
title = {Assessment of equivalent uniform RBE-weighted dose in hypofractionated proton therapy for ocular melanoma},
journal = {Biomedical Physics & Engineering Express},
year = {2025},
doi = {10.1088/2057-1976/adea7d}
}
EUVIMED