EUVIMEDEUVIMED entdecken
Crossref

Learning-based landmark detection in pelvis x-rays with attention mechanism: data from the osteoarthritis initiative

Yun Pei iD, Lin Mu, Chuanxin Xu, Qiang Li, Gan Sen, Bin Sun, Xiuying Li, Xueyan Li iD

Biomedical Physics & Engineering Express · 01.03.2023 · 9 (2) · 025001

DOI: 10.1088/2057-1976/ac8ffa ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Physics & Engineering Express, online erschienen am 04.01.2023. Verfasst von Yun Pei und 7 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun, 130012, People's Repu…. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Osteoarthritis. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 40 Literaturangaben. Gefördert von: Jilin Province Development and Reform Commission, National Natural Science Foundation of China, JLU Science and Technology Innovative Research Team.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Patients with developmental dysplasia of the hip can have this problem throughout their lifetime. The problem is difficult to detect by radiologists throughout x-ray because of an abrasion of anatomical structures. Thus, the landmarks should be automatically and precisely located. In this paper, we propose an attention mechanism of combining multi-dimension information on the basis of separating spatial dimension. The proposed attention mechanism decouples spatial dimension and forms width-channel dimension and height-channel dimension by 1D pooling operations in the height and width of spatial dimension. Then non-local means operations are performed to capture the correlation between long-range pixels in width-channel dimension, as well as that in height-channel dimension at different resolutions. The proposed attention mechanism modules are inserted into the skipped connections of U-Net to form a novel landmark detection structure. This landmark detection method was trained and evaluated through five-fold cross-validation on an open-source dataset, including 524 pelvis x-ray, each containing eight landmarks in pelvis, and achieved excellent performance compared to other landmark detection models. The average point-to-point errors of U-Net, HR-Net, CE-Net, and the proposed network were 3.5651 mm, 3.6118 mm, 3.3914 mm and 3.1350 mm, respectively. The results indicate that the proposed method has the highest detection accuracy. Furthermore, an open-source pelvis dataset is annotated and released for open research.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, X-Ray ComputedOsteoarthritisHumansX-RaysRadiographyPelvis

Stichwörter der Autor:innen

attention moduledeep learningdevelopmental dysplasia of the hiplandmark detection

Autor:innen und Institutionen

  • State Key Laboratory of Integrated Optoelectronics, College of Electronic Science and Engineering, Jilin University, Changchun, 130012, People's Republic of China.
  • Department of Radiology, The First Hospital of Jilin University, Changchun, 130021, People's Republic of China.
  • School of Electrical Engineering and Computer, Jilin Jianzhu University, Changchun, 130118, People's Republic of China.
  • Department of Orthopedics, the Second Hospital of Jilin University, Changchun, 130041, People's Republic of China.
  • Department of Medical Engineering and Technology, Xinjiang Medical University, Urumqi, 830011, People's Republic of China.
  • Peng Cheng Laboratory, Shenzhen, 518000, People's Republic of China.

ORCID-Profile: Yun Pei, Xueyan Li

Förderung

  • Jilin Province Development and Reform Commission
  • National Natural Science Foundation of China
  • JLU Science and Technology Innovative Research Team
  • Major scientific and technological program of Jilin Province

Zitieren

APA

Pei, Y., Mu, L., Xu, C., Li, Q., Sen, G., Sun, B., Li, X., & Li, X. (2023). Learning-based landmark detection in pelvis x-rays with attention mechanism: data from the osteoarthritis initiative. Biomedical Physics & Engineering Express, 9(2), 025001. https://doi.org/10.1088/2057-1976/ac8ffa

Vancouver

Pei Y, Mu L, Xu C, Li Q, Sen G, Sun B, et al. Learning-based landmark detection in pelvis x-rays with attention mechanism: data from the osteoarthritis initiative. Biomedical Physics & Engineering Express. 2023;9(2):025001. doi:10.1088/2057-1976/ac8ffa

BibTeX
@article{Pei2023,
  author = {Pei, Yun and Mu, Lin and Xu, Chuanxin and Li, Qiang and Sen, Gan and Sun, Bin and Li, Xiuying and Li, Xueyan},
  title = {Learning-based landmark detection in pelvis x-rays with attention mechanism: data from the osteoarthritis initiative},
  journal = {Biomedical Physics & Engineering Express},
  year = {2023},
  volume = {9},
  number = {2},
  pages = {025001},
  doi = {10.1088/2057-1976/ac8ffa}
}
Kostenlos starten →