FLIM quality metric visualization as a means to validate consistency across large-area non-homogeneous FLIM datasets
Methods and Applications in Fluorescence · 01.06.2026 · 14 (2) · 025004
DOI: 10.1088/2050-6120/ae4e7b ↗Kurz gefasst
Fachartikel in der Zeitschrift Methods and Applications in Fluorescence, online erschienen am 18.03.2026. Verfasst von Helen M Wilson und 4 weiteren Autor:innen. Beteiligte Einrichtung: University of Wisconsin, Laboratory for Optical and Computational Instrumentation, CQCI, Madison, WI, United States of America. Hauptthemen laut MEDLINE: Image Processing, Computer-Assisted. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NCI NIH HHS, NIBIB NIH HHS, National Institutes of Health.
Abstract (Originalsprache)
Robust and interpretable analysis of fluorescence lifetime imaging microscopy (FLIM) data requires careful assessment of data across biological samples. Due to limitations in sample availability, difference in protein expression, photobleaching, or acquisition time, FLIM datasets are often susceptible to signal variability. This is only exacerbated with large field-of-view FLIM data, such as examining metabolic fluxes across whole tissue slices due to morphology changes. We adapt the FLIM F-value (or figure-of-merit) within our analysis as a statistical metric to capture the confidence in lifetime by comparing variance across fitted parameters, analogous to typical image SNR. In this study, we apply pixelwise and regional analysis of F-values across large-area FLIM datasets to identify image regions with similar confidence levels. Visualization of F-value distribution enables detection of acquisition outliers or poor-quality regions within a large mosaic collection, which can be flagged for reacquisition or removal. This approach enhances the statistical power of downstream biological interpretation by ensuring that only data with quantifiable and stable lifetime information are retained. To our knowledge, this is the first application of F-value mapping as a dataset-wide quality control measure in FLIM.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- University of Wisconsin, Laboratory for Optical and Computational Instrumentation, CQCI, Madison, WI, United States of America.
- University of Wisconsin, Department of Biomedical Engineering, Madison, WI, United States of America.
- Morgridge Institute for Research, Madison, WI, United States of America.
- University of Minnesota, Department of Biomedical Engineering, Minneapolis, MN, United States of America.
- University of Wisconsin, Department of Medical Physics, Madison, WI, United States of America.
ORCID-Profile: Helen M Wilson, Jenu V Chacko, David J Odde, Paolo P Provenzano, Kevin W Eliceiri
Förderung
- NCI NIH HHS
- NIBIB NIH HHS
- National Institutes of Health
Zitieren
APA
Wilson, H. M., V Chacko, J., Odde, D. J., Provenzano, P. P., & Eliceiri, K. W. (2026). FLIM quality metric visualization as a means to validate consistency across large-area non-homogeneous FLIM datasets. Methods and Applications in Fluorescence, 14(2), 025004. https://doi.org/10.1088/2050-6120/ae4e7b
Vancouver
Wilson HM, V Chacko J, Odde DJ, Provenzano PP, Eliceiri KW. FLIM quality metric visualization as a means to validate consistency across large-area non-homogeneous FLIM datasets. Methods and Applications in Fluorescence. 2026;14(2):025004. doi:10.1088/2050-6120/ae4e7b
BibTeX
@article{Wilson2026,
author = {Wilson, Helen M and V Chacko, Jenu and Odde, David J and Provenzano, Paolo P and Eliceiri, Kevin W},
title = {FLIM quality metric visualization as a means to validate consistency across large-area non-homogeneous FLIM datasets},
journal = {Methods and Applications in Fluorescence},
year = {2026},
volume = {14},
number = {2},
pages = {025004},
doi = {10.1088/2050-6120/ae4e7b}
}
EUVIMED