Photonic crystal nanocavity refractive-index biosensor for multiple biological samples: a numerical study
Journal of Optics · 01.11.2026 · 28 (11) · 115301
DOI: 10.1088/2040-8986/aeb61b ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Optics, online erschienen am 16.11.2026. Verfasst von Shivesh Kumar und 3 weiteren Autor:innen. Die Arbeit nennt 79 Literaturangaben.
Abstract (Originalsprache)
This numerical study presents a two-dimensional (2D) photonic crystal (PhC) nanocavity biosensor based on a silicon slab for the refractive-index (RI) sensing of multiple biological samples, namely blood samples associated with tuberculosis, malaria, and dengue, and hemoglobin concentrations relevant to anemia assessment. The sensing performance is evaluated using the finite-difference time-domain (FDTD) method by analyzing the resonance wavelength shifts at the output port, while the photonic band structure is investigated using the plane-wave expansion method. A 20 nm shift of the cavity-adjacent air hole provides the best overall sensor performance. 2D FDTD simulations based on the effective-index method yield an idealized sensitivity of 453.85 nm RIU −1 , a quality factor (QF) of 1.7348 × 10 5 , a figure of merit (FOM) of 4.9740 × 10 4 RIU −1 , and a detection limit (DL) of 2.01045 × 10 −6 RIU for dengue-infected plasma. Full three-dimensional FDTD validation of the optimized design, which accounts for all radiative losses, gives a sensitivity of approximately 315 nm RIU −1 , a QF of 1.39 × 10 4 , a FOM of 2.79 × 10 3 RIU −1 , and a DL of 3.59 × 10 −5 RIU for the same analyte. These results confirm the linear RI response of the sensor ( R 2 ≥ 0.9996 ), while showing that the 2D model overestimates the absolute QF by approximately one order of magnitude. The sensor also exhibits a linear and predictable thermal response of 98.8 pm °C −1 over the range of 0 °C–60 °C, which can be used for temperature calibration. A comparison with reported PhC sensors indicates that the proposed design is competitive. A fabrication-tolerance analysis shows that satisfactory sensing performance is maintained under random deviations in hole radius and position of up to 20 nm. With a compact footprint of 76.5 μ m 2 and compatibility with single-step lithography on a silicon-on-insulator platform, the proposed sensor is a promising candidate for label-free RI sensing in photonic integrated circuits. Surface functionalization and experimental validation will be required for disease-specific detection.
Zitieren
APA
Kumar, S., Pradhan, A. K., Yadav, K., & Kumar, M. (2026). Photonic crystal nanocavity refractive-index biosensor for multiple biological samples: a numerical study. Journal of Optics, 28(11), 115301. https://doi.org/10.1088/2040-8986/aeb61b
Vancouver
Kumar S, Pradhan AK, Yadav K, Kumar M. Photonic crystal nanocavity refractive-index biosensor for multiple biological samples: a numerical study. Journal of Optics. 2026;28(11):115301. doi:10.1088/2040-8986/aeb61b
BibTeX
@article{Kumar2026,
author = {Kumar, Shivesh and Pradhan, Akash Kumar and Yadav, Kuldeep and Kumar, Manoj},
title = {Photonic crystal nanocavity refractive-index biosensor for multiple biological samples: a numerical study},
journal = {Journal of Optics},
year = {2026},
volume = {28},
number = {11},
pages = {115301},
doi = {10.1088/2040-8986/aeb61b}
}
EUVIMED