EUVIMEDEUVIMED entdecken
Crossref

Selective Correction of Condition-Sensitive Parameters for Cross-Condition Torque Prediction in an EMG-Driven Elbow Musculoskeletal Model

Jianshe Gao, Yu Wang iD, Xiaobo Rao, Xingzhao Guo iD, Qiang Liu iD, Jie Wang iD

Medical Engineering & Physics · 06.11.2026

DOI: 10.1088/1873-4030/aebecf ↗

Kurz gefasst

Fachartikel in der Zeitschrift Medical Engineering & Physics, online erschienen am 06.11.2026. Verfasst von Jianshe Gao und 5 weiteren Autor:innen. Beteiligte Einrichtung: Zhengzhou University, School of Mechanical and Power Engineering, Zhengzhou University, Zhengzhou, China, Zhengzhou, Henan, 450001, China. Gefördert von: National Natural Science Foundation of China, Henan Provincial Association for Science and Technology Youth Talent Lifting Project, Natural Science Foundation of Henan Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Electromyography-driven musculoskeletal models estimate muscle forces and joint torque. A shared parameter set can leave errors that vary with movement speed and load. This study examined selective condition correction in an EMG-driven elbow model. The model retained a common parameter set and added speed- and load-dependent terms only to selected parameters. Ten healthy participants performed constrained isokinetic elbow flexion-extension. Subject-specific MuJoCo models were constructed from OpenSim arm26. Speed-Load had the lowest mean validation RMSE among three calibration combinations (1.37 N·m) and was used for common calibration. Length-range constraints were included during fitting. Full reduced mean RMSE by 10.0-18.6% across held-out repetitions, interpolation and extrapolation conditions. The largest reduction occurred in extrapolation: RMSE decreased from 2.08 to 1.70 N·m, while mean R² increased from 0.71 to 0.81. The ablation models had intermediate mean errors. The full two-stage procedure improved within-subject torque prediction across the tested speed and target-torque conditions with a limited number of additional coefficients.

Schlagwörter

Stichwörter der Autor:innen

EMG-driven musculoskeletal modelparameter calibrationselective condition correctionupper-limb rehabilitation

Autor:innen und Institutionen

  • Zhengzhou University, School of Mechanical and Power Engineering, Zhengzhou University, Zhengzhou, China, Zhengzhou, Henan, 450001, China.
  • The Third People's Hospital of Henan Province, The Third People's Hospital of Henan Province, Zhengzhou, Henan, 450018, China.
  • School of Mechanical and Power Engineering, Zhengzhou University, No. 100, Kexue Avenue, Zhengzhou, Henan, 450001, China.

ORCID-Profile: Yu Wang, Xingzhao Guo, Qiang Liu, Jie Wang

Förderung

  • National Natural Science Foundation of China
  • Henan Provincial Association for Science and Technology Youth Talent Lifting Project
  • Natural Science Foundation of Henan Province
  • Henan Provincial Key R&D Program

Zitieren

APA

Gao, J., Wang, Y., Rao, X., Guo, X., Liu, Q., & Wang, J. (2026). Selective Correction of Condition-Sensitive Parameters for Cross-Condition Torque Prediction in an EMG-Driven Elbow Musculoskeletal Model. Medical Engineering & Physics. https://doi.org/10.1088/1873-4030/aebecf

Vancouver

Gao J, Wang Y, Rao X, Guo X, Liu Q, Wang J. Selective Correction of Condition-Sensitive Parameters for Cross-Condition Torque Prediction in an EMG-Driven Elbow Musculoskeletal Model. Medical Engineering & Physics. 2026. doi:10.1088/1873-4030/aebecf

BibTeX
@article{Gao2026,
  author = {Gao, Jianshe and Wang, Yu and Rao, Xiaobo and Guo, Xingzhao and Liu, Qiang and Wang, Jie},
  title = {Selective Correction of Condition-Sensitive Parameters for Cross-Condition Torque Prediction in an EMG-Driven Elbow Musculoskeletal Model},
  journal = {Medical Engineering & Physics},
  year = {2026},
  doi = {10.1088/1873-4030/aebecf}
}
Kostenlos starten →