EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Open-loop system identification of an AC motor-driven arterial flow generation platform: vessel-specific models and a parsimonious common ARX model

Serdar Yilmaz iD, Hüseyin Yıldız iD, Canan Akay, Feyzi Kaysi iD, Herman Sedef

Medical Engineering & Physics · 02.11.2026 · 147 (11) · 115013

DOI: 10.1088/1873-4030/aebb2f ↗

Kurz gefasst

Fachartikel in der Zeitschrift Medical Engineering & Physics, online erschienen am 10.11.2026. Verfasst von Serdar Yilmaz und 4 weiteren Autor:innen. Beteiligte Einrichtung: Electronics Technology, Vocational School of Technical Sciences, Istanbul University-Cerrahpasa, Istanbul 34500, Türkiye. Hauptthemen laut MEDLINE: Arteries, Models, Biological. Die Arbeit nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurate reproduction of arterial flow waveforms is important forin vitrocardiovascular experiments and controlled biomedical flow platforms. This study characterizes the open-loop dynamics of an AC motor-inverter-centrifugal-pump platform using five experimentally recorded input-output datasets representing femoral, carotid, iliac, coronary, and aortic waveform conditions. The inverter command was the input, the magnetic flow-meter voltage was the output, and all original recordings were sampled at 100 Hz. Vessel-specific FIR, ARX, and ridge-regularized ARX models were screened separately. A common model was selected using nested chronological validation and assessed on untouched test segments using one-step prediction, recursive free-run simulation, and diagnostic analyses. Vessel-specific one-step validation fits ranged from 80.18%-92.80%. The common ARX(5,4,80) model achieved mean one-step and free-run fits of 95.82% and 80.04%, respectively. All poles were inside the unit circle, but significant residual autocorrelation showed that the measured response was not fully explained. The common model provides a compact nominal representation of the tested platform. Its comparison with vessel-specific models is descriptive because it uses more training data, and cycle consistency within a recording does not establish between-session experimental reproducibility.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ArteriesModels, Biological

Stichwörter der Autor:innen

ARX modelarterial flow waveformfree-run validationmulti-experiment modelingopen-loop system identificationresidual analysisridge regularization

Autor:innen und Institutionen

  • Electronics Technology, Vocational School of Technical Sciences, Istanbul University-Cerrahpasa, Istanbul 34500, Türkiye.
  • Department of Mechanical Engineering, Mechatronics Division, Istanbul University-Cerrahpasa, Faculty of Engineering, Istanbul 34320, Türkiye.
  • Control and Automation Technology, Vocational School of Technical Sciences, Istanbul University-Cerrahpasa, Istanbul 34500, Türkiye.
  • Faculty of Electrical and Electronics, Department of Electronics and Communications Engineering, Circuits and Systems, Yildiz Technical University, Istanbul, Türkiye.

ORCID-Profile: Serdar Yilmaz, Hüseyin Yıldız, Feyzi Kaysi

Zitieren

APA

Yilmaz, S., Yıldız, H., Akay, C., Kaysi, F., & Sedef, H. (2026). Open-loop system identification of an AC motor-driven arterial flow generation platform: vessel-specific models and a parsimonious common ARX model. Medical Engineering & Physics, 147(11), 115013. https://doi.org/10.1088/1873-4030/aebb2f

Vancouver

Yilmaz S, Yıldız H, Akay C, Kaysi F, Sedef H. Open-loop system identification of an AC motor-driven arterial flow generation platform: vessel-specific models and a parsimonious common ARX model. Medical Engineering & Physics. 2026;147(11):115013. doi:10.1088/1873-4030/aebb2f

BibTeX
@article{Yilmaz2026,
  author = {Yilmaz, Serdar and Yıldız, Hüseyin and Akay, Canan and Kaysi, Feyzi and Sedef, Herman},
  title = {Open-loop system identification of an AC motor-driven arterial flow generation platform: vessel-specific models and a parsimonious common ARX model},
  journal = {Medical Engineering & Physics},
  year = {2026},
  volume = {147},
  number = {11},
  pages = {115013},
  doi = {10.1088/1873-4030/aebb2f}
}
Kostenlos starten →