The optimization and comparison of two high-throughput faecal headspace sampling platforms: the microchamber/thermal extractor and hi-capacity sorptive extraction probes (HiSorb)
Journal of Breath Research · 2024
DOI: 10.1088/1752-7163/ad2002 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Breath Research, 2024. Verfasst von Robert van Vorstenbosch und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pharmacology and Toxicology, NUTRIM School of Nutrition and Translational Research, Maastricht University, Maastricht, The Netherlands. Hauptthemen laut MEDLINE: Volatile Organic Compounds, Body Fluids. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: KWF Kankerbestrijding.
Abstract (Originalsprache)
Disease detection and monitoring using volatile organic compounds (VOCs) is becoming increasingly popular. For a variety of (gastrointestinal) diseases the microbiome should be considered. As its output is to large extent volatile, faecal volatilomics carries great potential. One technical limitation is that current faecal headspace analysis requires specialized instrumentation which is costly and typically does not work in harmony with thermal desorption units often utilized in e.g. exhaled breath studies. This lack of harmonization hinders uptake of such analyses by the Volatilomics community. Therefore, this study optimized and compared two recently harmonized faecal headspace sampling platforms: High-capacity Sorptive extraction (HiSorb) probes and the Microchamber thermal extractor (Microchamber) . Statistical design of experiment was applied to find optimal sampling conditions by maximizing reproducibility, the number of VOCs detected, and between subject variation. To foster general applicability those factors were defined using semi-targeted as well as untargeted metabolic profiles. HiSorb probes were found to result in a faster sampling procedure, higher number of detected VOCs, and higher stability. The headspace collection using the Microchamber resulted in a lower number of detected VOCs, longer sampling times and decreased stability despite a smaller number of interfering VOCs and no background signals. Based on the observed profiles, recommendations are provided on pre-processing and study design when using either one of both platforms. Both can be used to perform faecal headspace collection, but altogether HiSorb is recommended.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Pharmacology and Toxicology, NUTRIM School of Nutrition and Translational Research, Maastricht University, Maastricht, The Netherlands.
ORCID-Profile: Robert van Vorstenbosch, Agnieszka Smolinska
Förderung
- KWF Kankerbestrijding
Zitieren
APA
van Vorstenbosch, R., Mommers, A., Pachen, D., van Schooten, F. J., & Smolinska, A. (2024). The optimization and comparison of two high-throughput faecal headspace sampling platforms: the microchamber/thermal extractor and hi-capacity sorptive extraction probes (HiSorb). Journal of Breath Research. https://doi.org/10.1088/1752-7163/ad2002
Vancouver
van Vorstenbosch R, Mommers A, Pachen D, van Schooten FJ, Smolinska A. The optimization and comparison of two high-throughput faecal headspace sampling platforms: the microchamber/thermal extractor and hi-capacity sorptive extraction probes (HiSorb). Journal of Breath Research. 2024. doi:10.1088/1752-7163/ad2002
BibTeX
@article{vanVorstenbosch2024,
author = {van Vorstenbosch, Robert and Mommers, Alex and Pachen, Daniëlle and van Schooten, Frederik-Jan and Smolinska, Agnieszka},
title = {The optimization and comparison of two high-throughput faecal headspace sampling platforms: the microchamber/thermal extractor and hi-capacity sorptive extraction probes (HiSorb)},
journal = {Journal of Breath Research},
year = {2024},
doi = {10.1088/1752-7163/ad2002}
}
EUVIMED