EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Effect of valve spacing on peristaltic pumping

Ki Tae Wolf, Amir Poorghani, J Brandon Dixon, Alexander Alexeev iD

Bioinspiration & Biomimetics · 01.05.2023 · 18 (3) · 035002

DOI: 10.1088/1748-3190/acbe85 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Bioinspiration & Biomimetics, online erschienen am 09.03.2023. Verfasst von Ki Tae Wolf und 3 weiteren Autor:innen. Beteiligte Einrichtung: George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, United States of America. Hauptthemen laut MEDLINE: Models, Biological, Peristalsis. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NHLBI NIH HHS, National Institutes of Health.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Peristaltic fluid pumping due to a periodically propagating contraction wave in a vessel fitted with one-way elastic valves is investigated numerically. It is concluded that the valve spacing within the vessel relative to the contraction wavelength plays a critical role in providing efficient pumping. When the valve spacing does not match the wavelength, the valves open asynchronously and the volume of the vessel segments bounded by two consecutive valves changes periodically, thereby inducing volumetric fluid pumping. The volumetric pumping leads to higher pumping flowrate and efficiency against an adverse pressure gradient. The optimum pumping occurs when the ratio of valve spacing to contraction wavelength is about 2 / 3 . This pumping regime is characterized by a longer period during which the valves are open. The results are useful for further understanding the pumping features of lymphatic system and provide insight into the design of biomimetic pumping devices.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Models, BiologicalPeristalsis

Stichwörter der Autor:innen

elastic valvesflow-vessel interactionperistaltic micro pumpingvalve spacing

Autor:innen und Institutionen

  • George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, United States of America.
  • Petit Institute for Bioengineering and Bioscience, Georgia Institute of Technology, Atlanta, GA 30332, United States of America.
  • Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, United States of America.

ORCID-Profile: Alexander Alexeev

Förderung

  • NHLBI NIH HHS
  • National Institutes of Health

Zitieren

APA

Wolf, K. T., Poorghani, A., Dixon, J. B., & Alexeev, A. (2023). Effect of valve spacing on peristaltic pumping. Bioinspiration & Biomimetics, 18(3), 035002. https://doi.org/10.1088/1748-3190/acbe85

Vancouver

Wolf KT, Poorghani A, Dixon JB, Alexeev A. Effect of valve spacing on peristaltic pumping. Bioinspiration & Biomimetics. 2023;18(3):035002. doi:10.1088/1748-3190/acbe85

BibTeX
@article{Wolf2023,
  author = {Wolf, Ki Tae and Poorghani, Amir and Dixon, J Brandon and Alexeev, Alexander},
  title = {Effect of valve spacing on peristaltic pumping},
  journal = {Bioinspiration & Biomimetics},
  year = {2023},
  volume = {18},
  number = {3},
  pages = {035002},
  doi = {10.1088/1748-3190/acbe85}
}
Kostenlos starten →