Stimulus classification with electrical potential and impedance of living plants: comparing discriminant analysis and deep-learning methods
Bioinspiration & Biomimetics · 01.03.2023 · 18 (2) · 025003
DOI: 10.1088/1748-3190/acbad2 ↗Kurz gefasst
Fachartikel in der Zeitschrift Bioinspiration & Biomimetics, online erschienen am 07.03.2023. Verfasst von Eduard Buss und 5 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Computer Engineering, University of Lübeck, Lübeck, Germany. Hauptthemen laut MEDLINE: Deep Learning. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 59 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: EU-ICT project WatchPlant - Smart Biohybrid Phyto-Organisms for Environmental In Situ Monitoring.
Abstract (Originalsprache)
The physiology of living organisms, such as living plants, is complex and particularly difficult to understand on a macroscopic, organism-holistic level. Among the many options for studying plant physiology, electrical potential and tissue impedance are arguably simple measurement techniques that can be used to gather plant-level information. Despite the many possible uses, our research is exclusively driven by the idea of phytosensing, that is, interpreting living plants’ signals to gather information about surrounding environmental conditions. As ready-to-use plant-level physiological models are not available, we consider the plant as a blackbox and apply statistics and machine learning to automatically interpret measured signals. In simple plant experiments, we expose Zamioculcas zamiifolia and Solanum lycopersicum (tomato) to four different stimuli: wind, heat, red light and blue light. We measure electrical potential and tissue impedance signals. Given these signals, we evaluate a large variety of methods from statistical discriminant analysis and from deep learning, for the classification problem of determining the stimulus to which the plant was exposed. We identify a set of methods that successfully classify stimuli with good accuracy, without a clear winner. The statistical approach is competitive, partially depending on data availability for the machine learning approach. Our extensive results show the feasibility of the blackbox approach and can be used in future research to select appropriate classifier techniques for a given use case. In our own future research, we will exploit these methods to derive a phytosensing approach to monitoring air pollution in urban areas.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institute of Computer Engineering, University of Lübeck, Lübeck, Germany.
- Department of Computer and Information Science, University of Konstanz, Konstanz, Germany.
- CYBRES GmbH, Research Center of Advanced Robotics and Environmental Science, Stuttgart, Germany.
ORCID-Profile: Eduard Buss, Till Aust, Mostafa Wahby, Tim-Lucas Rabbel, Serge Kernbach, Heiko Hamann
Förderung
- EU-ICT project WatchPlant - Smart Biohybrid Phyto-Organisms for Environmental In Situ Monitoring
Zitieren
APA
Buss, E., Aust, T., Wahby, M., Rabbel, T. L., Kernbach, S., & Hamann, H. (2023). Stimulus classification with electrical potential and impedance of living plants: comparing discriminant analysis and deep-learning methods. Bioinspiration & Biomimetics, 18(2), 025003. https://doi.org/10.1088/1748-3190/acbad2
Vancouver
Buss E, Aust T, Wahby M, Rabbel TL, Kernbach S, Hamann H. Stimulus classification with electrical potential and impedance of living plants: comparing discriminant analysis and deep-learning methods. Bioinspiration & Biomimetics. 2023;18(2):025003. doi:10.1088/1748-3190/acbad2
BibTeX
@article{Buss2023,
author = {Buss, Eduard and Aust, Till and Wahby, Mostafa and Rabbel, Tim-Lucas and Kernbach, Serge and Hamann, Heiko},
title = {Stimulus classification with electrical potential and impedance of living plants: comparing discriminant analysis and deep-learning methods},
journal = {Bioinspiration & Biomimetics},
year = {2023},
volume = {18},
number = {2},
pages = {025003},
doi = {10.1088/1748-3190/acbad2}
}
EUVIMED