Impact of helium cooling channels and flow channel inserts on magnetohydrodynamic mixed convection in a liquid metal blanket.
Nuclear Fusion · 17.11.2026
DOI: 10.1088/1741-4326/aec30c ↗Kurz gefasst
Fachartikel in der Zeitschrift Nuclear Fusion, online erschienen am 17.11.2026. Verfasst von Qi-Xian Hu und 4 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Key Programme, Chinese Academy of Science and Technology Service Network Planning.
Abstract (Originalsprache)
On the pathway toward full simulations for a liquid metal blanket, this study extends the work of Chen et al (2022 Nucl. Fusion 62 026042) on mixed convection in a full-scale dual coolant lead lithium blanket by considering a more realistic case. In this study, the model incorporates the complex geometry of characteristic sub-components, including helium cooling channels and flow channel inserts (FCIs), to investigate their impacts in several key metrics :(1) Magnetohydrodynamic (MHD) pressure drop, (2) electromagnetic coupling, (3) velocity distribution in both the bulk and gap regions, (4) flow behavior in blanket components, and (5) heat transfer. Based on the MHD-UCAS platform, these multi-region, multiphysics direct numerical simulations are performed on a highly refined mesh of 5.46 × 10 8 cells under conditions relevant to the fusion reactor: the applied magnetic field of 5 T ( Ha ∼10 4 ), the PbLi velocity of 0.1 ms -1 in poloidal ducts ( Re ∼10 5 ), and maximum volumetric heating of 30 MW m -3 ( Gr ∼10 12 ). The computational results incorporate the influence of the helium cooling channels and the FCIs on electromagnetic coupling, thereby altering the MHD pressure and flow distribution. Simultaneously, the FCIs divide the flow into bulk and gap regions, where high-speed reverse flows are identified exclusively within the gap regions of the rear poloidal ducts. The anisotropic conductivity introduced by helium channels alters the velocity and temperature distributions, further complicating the MHD flow. In addition, localized hot spots exceeding the design temperature limit are found near the top of the U-turn and in the outlet reduced activation ferritic/martensitic steel walls, suggesting that enhanced cooling is required in these locations.
Förderung
- Key Programme
- Chinese Academy of Science and Technology Service Network Planning
Zitieren
APA
Hu, Q., Zheng, X., Xu, H., Chen, L., & Ni, M. (2026). Impact of helium cooling channels and flow channel inserts on magnetohydrodynamic mixed convection in a liquid metal blanket. Nuclear Fusion. https://doi.org/10.1088/1741-4326/aec30c
Vancouver
Hu Q, Zheng X, Xu H, Chen L, Ni M. Impact of helium cooling channels and flow channel inserts on magnetohydrodynamic mixed convection in a liquid metal blanket. Nuclear Fusion. 2026. doi:10.1088/1741-4326/aec30c
BibTeX
@article{Hu2026,
author = {Hu, Qi-Xian and Zheng, Xuan and Xu, Hai-Bo and Chen, Long and Ni, Mingjiu},
title = {Impact of helium cooling channels and flow channel inserts on magnetohydrodynamic mixed convection in a liquid metal blanket},
journal = {Nuclear Fusion},
year = {2026},
doi = {10.1088/1741-4326/aec30c}
}