EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Comparison of divertor heat loads and access to detachment for n = 3 and n = 4 toroidal mode RMP scenarios in ITER

J. Van Blarcum, H. Frerichs, L. Li, Y.Q. Liu, A. Loarte, R.A. Pitts, O. Schmitz

Nuclear Fusion · 01.05.2026 · 66 (5) · 056029

DOI: 10.1088/1741-4326/ae5d52 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Nuclear Fusion, online erschienen am 22.04.2026. Verfasst von J. Van Blarcum und 6 weiteren Autor:innen. Die Arbeit nennt 53 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Basic Energy Sciences, ITER Organization.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A comparison of partial detachment and divertor heat loads is made for n = 3 and n = 4 toroidal mode resonant magnetic perturbation (RMP) scenarios for ITER. X -point displacement ( ξ X ) , a figure of merit for edge localized mode suppression calculated by the MARS-F plasma response code, is used to select RMP configurations. For equivalent ξ X the resulting intersection of the perturbed helical corrugations of the magnetic separatrix and divertor target (i.e. the magnetic footprints) extend 37.1 cm from the original strike point for the n = 4 scenario, compared to 21.2 cm for the n = 3. A hybrid n = 3 & 4 mode which superimposes contributions from both modes is also explored. For each RMP scenario and a no-RMP reference, a 7-step scan of the main ion injection rate transitions EMC3-EIRENE simulations of the perturbed scrape-off layer (SOL) from attached to partially detached solutions. The low-density (i.e. attached regime) simulations show that the reorganization of the SOL into the toroidally discrete helical lobes localizes power deposition on the target, increasing peak heat loads from 4.5 MWm − 2 in no-RMP reference to 5.9 and 4.7 MWm − 2 in the n = 3 and n = 4 scenarios respectively. The peak heat load increases to 9.2 MWm − 2 in the n = 3 & 4 scenario because the heat load becomes further biased towards a single lobe structure. The partially detached SOL simulations show that it is more difficult to mitigate peak heat loads in the larger magnetic footprint scenario ( n = 4) where the peak heat load occurs further along the lobe structure, away from the original equilibrium strike point.

Förderung

  • Basic Energy Sciences
  • ITER Organization

Zitieren

APA

Blarcum, J. V., Frerichs, H., Li, L., Liu, Y., Loarte, A., Pitts, R., & Schmitz, O. (2026). Comparison of divertor heat loads and access to detachment for n = 3 and n = 4 toroidal mode RMP scenarios in ITER. Nuclear Fusion, 66(5), 056029. https://doi.org/10.1088/1741-4326/ae5d52

Vancouver

Blarcum JV, Frerichs H, Li L, Liu Y, Loarte A, Pitts R, et al. Comparison of divertor heat loads and access to detachment for n = 3 and n = 4 toroidal mode RMP scenarios in ITER. Nuclear Fusion. 2026;66(5):056029. doi:10.1088/1741-4326/ae5d52

BibTeX
@article{Blarcum2026,
  author = {Blarcum, J. Van and Frerichs, H. and Li, L. and Liu, Y.Q. and Loarte, A. and Pitts, R.A. and Schmitz, O.},
  title = {Comparison of divertor heat loads and access to detachment for n = 3 and n = 4 toroidal mode RMP scenarios in ITER},
  journal = {Nuclear Fusion},
  year = {2026},
  volume = {66},
  number = {5},
  pages = {056029},
  doi = {10.1088/1741-4326/ae5d52}
}
Kostenlos starten →