Power sharing in WEST double-null plasmas
Nuclear Fusion · 01.05.2026 · 66 (5) · 056005
DOI: 10.1088/1741-4326/ae511c ↗Kurz gefasst
Fachartikel in der Zeitschrift Nuclear Fusion, online erschienen am 30.03.2026. Verfasst von D. Moiraf und 14 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 96 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: EUROfusion.
Abstract (Originalsprache)
This study investigates L-mode power sharing between divertor target plates in double-null (DN) magnetic configuration on the tungsten (W) Environment Steady-state Tokamak (WEST). A series of discharges scanning the distance between the separatrices at the outer mid-plane ( δ R sep ) were analyzed using Langmuir probes, embedded fiber Bragg gratings (FBGs), and calorimetry to characterize heat flux profiles and total deposited power in attached regime. Results show that DN configurations could significantly reduce the peak heat flux measured by FBGs on the lower divertor by over 70% compared to Lower Single-Null as power is more evenly distributed between upper and lower divertors. However, the heat flux is shown to be highly sensitive (peak value multiplied by 2) to millimetric variations of the δ R sep . These findings reinforce the DN configuration’s potential for mitigating peak heat loads in next step fusion devices, while highlighting the need for precise magnetic control in attached regime. Power deposition remains asymmetric in connected DN, with up to 89% of power directed to outer targets and 68% to the lower divertor, consistent with the ballooned nature of radial transport at the low-field side and downward B B × ∇ ∇ B drift effects. To quantify these effects, we develop a revised power sharing model building on Brunner’s formulation, incorporating localized sources at the inner ( S i ) and outer ( S o ) mid-plane, a vertical drift bias b , and a cooling factor κ diss . The best-fit parameters suggest that approximately 58% of the exhaust power preferentially flows downward due to vertical drifts, and that a secondary inner mid-plane source contributes up to 13% of the total power in WEST. The decay lengths obtained from the fit are in agreement with those independently measured from heat flux profiles, further validating the model.
Förderung
- EUROfusion
Zitieren
APA
Moiraf, D., Fedorczak, N., Ciraolo, G., Anquetin, Y., Corre, Y., Gaspar, J., Gerardin, J., Grosjean, A., Gunn, J., Morales, J., Nouailletas, R., Redaud, J., Rivals, N., Tamain, P., & Traversari, D. (2026). Power sharing in WEST double-null plasmas. Nuclear Fusion, 66(5), 056005. https://doi.org/10.1088/1741-4326/ae511c
Vancouver
Moiraf D, Fedorczak N, Ciraolo G, Anquetin Y, Corre Y, Gaspar J, et al. Power sharing in WEST double-null plasmas. Nuclear Fusion. 2026;66(5):056005. doi:10.1088/1741-4326/ae511c
BibTeX
@article{Moiraf2026,
author = {Moiraf, D. and Fedorczak, N. and Ciraolo, G. and Anquetin, Y. and Corre, Y. and Gaspar, J. and Gerardin, J. and Grosjean, A. and Gunn, J. and Morales, J. and Nouailletas, R. and Redaud, J. and Rivals, N. and Tamain, P. and Traversari, D.},
title = {Power sharing in WEST double-null plasmas},
journal = {Nuclear Fusion},
year = {2026},
volume = {66},
number = {5},
pages = {056005},
doi = {10.1088/1741-4326/ae511c}
}
EUVIMED