EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Enhanced source localization accuracy through bidirectional deep brain stimulation (DBS) electrodes: a comparative study with non-invasive EEG methods

Babatunde Abdullahi Olatunji iD, Narayan Puthanmadam Subramaniyam iD, Eetu Siitama iD, Herkko Mattila iD, Kai Lehtimäki iD, Jari Hyttinen iD, Jukka Peltola iD, Sampsa Pursiainen iD

Journal of Neural Engineering · 01.08.2026 · 23 (4) · 046028

DOI: 10.1088/1741-2552/ae87d0 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Neural Engineering, online erschienen am 21.07.2026. Verfasst von Babatunde Abdullahi Olatunji und 7 weiteren Autor:innen. Beteiligte Einrichtung: Biomedical Technology Unit, Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland. Hauptthemen laut MEDLINE: Deep Brain Stimulation, Electroencephalography, Electrodes, Implanted, Brain. Die Arbeit nennt 66 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: DREAM doctoral education pilot project, Bilateral Münster-Tampere researcher exchange project "Spatio-temporal source reconstruction in visual cortex and in focal epilepsy" DAAD/The Research Council…, Research Council of Finland.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective . Accurate neural source localization from electroencephalography (EEG) remains challenging for deep brain structures. This study investigates whether integrating bidirectional deep brain stimulation (DBS) electrodes with conventional scalp-EEG can improve source localization accuracy, particularly under varying signal-to-noise ratio (SNR) conditions. While bidirectional DBS leads support both passive recording and active stimulation-based probing of neural circuits, this study focuses exclusively on passive recording capabilities. Approach . We evaluated three bidirectional DBS electrode configurations (4-contact, 8-contact, and 40-contact arrays) combined with 72-channel scalp-EEG using finite element method-based forward modeling. An extended complete electrode model framework was applied here for the first time to model both scalp and DBS electrodes, incorporating realistic electrode-tissue impedance characteristics and locally refined meshes. Source reconstruction was performed using standardized low-resolution electromagnetic tomography (sLORETA) and dipole scan techniques across three SNR conditions (30 dB, 17.5 dB, and 5 dB). Forward and inverse solutions were computed within the Zeffiro Interface framework using source spaces defined for whole-brain, thalamus, and hippocampus-focused analyses. Main Results . Integrating bidirectional DBS and scalp-EEG electrodes significantly improved source localization accuracy, with improvements strongest in regions proximal to the implanted lead. The 40-contact configuration produced the largest gains, while the 8-contact configuration offered the best balance between accuracy and electrode complexity. Dipole scan achieved near-perfect localization (0.0 mm at 30 dB), whereas sLORETA remained comparatively stable across broader regional analyses for both single- and two-source scenarios. Significance . Integrating scalp-EEG with bidirectional DBS electrode recordings represents a promising approach for deep brain source localization. The complementary strengths of scalp arrays (broad orientational coverage) and DBS contacts (high-SNR proximal measurements) can be leveraged across source configurations, reconstruction algorithms, and noise conditions. This multimodal strategy holds particular promise for post-implantation epilepsy monitoring, adaptive neuromodulation biomarker discovery, and understanding deep-to-cortical seizure propagation dynamics in patients already receiving DBS therapy.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Deep Brain StimulationElectroencephalographyElectrodes, ImplantedBrainBrain MappingHumans

Stichwörter der Autor:innen

Bidirectional deep brain stimulationEEG source localizationcomplete electrode modeldipole scandrug-resistant epilepsyfinite element methodsLORETA

Autor:innen und Institutionen

  • Biomedical Technology Unit, Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland.
  • Department of Medical Physics, Neurocenter Finland, Tampere Brain and Mind, Tampere University Hospital, Wellbeing Services County of Pirkanmaa, Tampere, Finland.
  • Department of Neurosurgery, Faculty of Medicine and Health Technology, Tampere University and Tampere University Hospital, Tampere, Finland.
  • Department of Neurology, Faculty of Medicine and Health Technology, Tampere University and Tampere University Hospital, Tampere, Finland.
  • Mathematics Research Center, Tampere University, Tampere, Finland.

ORCID-Profile: Babatunde Abdullahi Olatunji, Narayan Puthanmadam Subramaniyam, Eetu Siitama, Herkko Mattila, Kai Lehtimäki, Jari Hyttinen, Jukka Peltola, Sampsa Pursiainen

Förderung

  • DREAM doctoral education pilot project
  • Bilateral Münster-Tampere researcher exchange project "Spatio-temporal source reconstruction in visual cortex and in focal epilepsy" DAAD/The Research Council…
  • Research Council of Finland

Zitieren

APA

Olatunji, B. A., Subramaniyam, N. P., Siitama, E., Mattila, H., Lehtimäki, K., Hyttinen, J., Peltola, J., & Pursiainen, S. (2026). Enhanced source localization accuracy through bidirectional deep brain stimulation (DBS) electrodes: a comparative study with non-invasive EEG methods. Journal of Neural Engineering, 23(4), 046028. https://doi.org/10.1088/1741-2552/ae87d0

Vancouver

Olatunji BA, Subramaniyam NP, Siitama E, Mattila H, Lehtimäki K, Hyttinen J, et al. Enhanced source localization accuracy through bidirectional deep brain stimulation (DBS) electrodes: a comparative study with non-invasive EEG methods. Journal of Neural Engineering. 2026;23(4):046028. doi:10.1088/1741-2552/ae87d0

BibTeX
@article{Olatunji2026,
  author = {Olatunji, Babatunde Abdullahi and Subramaniyam, Narayan Puthanmadam and Siitama, Eetu and Mattila, Herkko and Lehtimäki, Kai and Hyttinen, Jari and Peltola, Jukka and Pursiainen, Sampsa},
  title = {Enhanced source localization accuracy through bidirectional deep brain stimulation (DBS) electrodes: a comparative study with non-invasive EEG methods},
  journal = {Journal of Neural Engineering},
  year = {2026},
  volume = {23},
  number = {4},
  pages = {046028},
  doi = {10.1088/1741-2552/ae87d0}
}
Kostenlos starten →