EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte StudieOpen Access · CC BY 4.0

Broad vs narrow focus: how frequency and focal size affect transcranial ultrasound stimulation in motor cortex

Ali K Zadeh iD, Alan Coreas, Shirshak Shrestha, Iris Kathol, Davide Martino iD, G Bruce Pike iD, Samuel Pichardo iD, Oury Monchi iD

Journal of Neural Engineering · 01.06.2026 · 23 (3) · 036031

DOI: 10.1088/1741-2552/ae730a ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Journal of Neural Engineering, online erschienen am 09.06.2026. Verfasst von Ali K Zadeh und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Neurosciences, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada. Hauptthemen laut MEDLINE: Motor Cortex, Evoked Potentials, Motor. Die Arbeit nennt 60 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Canada Foundation for Innovation, NSERC BRAIN CREATE, Natural Sciences and Engineering Research Council of Canada.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective. Transcranial ultrasound stimulation (TUS) is a noninvasive neuromodulation technique offering millimeter-scale precision and deep targeting. However, the trade-off between fundamental frequency, focal size, and efficacy in humans remains unclear. This study aimed to compare the effects of broad versus narrow acoustic focus on corticospinal excitability using 250 kHz and 825 kHz TUS, and to evaluate whether multi-focal stimulation mitigates limitations of narrow beams. Approach. Twenty healthy adults underwent four randomized, double-blind sessions: 250 kHz unifocal, 825 kHz unifocal, 825 kHz multi-focal, and sham. TUS was delivered to the left primary motor cortex using a 128-element phased-array transducer integrated with neuronavigation. Corticospinal excitability was assessed using motor-evoked potentials (MEPs) elicited by transcranial magnetic stimulation at baseline and 5-, 30-, and 60 min post-stimulation. Reaction (RT) time and accuracy were measured using a Go/No-Go task. Main results. Linear mixed-effects modeling revealed a significant inhibition of corticospinal excitability, characterized by decreased MEP amplitudes, for both the 250 kHz unifocal and 825 kHz multi-focal conditions compared to sham (both with p = 0.018). The 825 kHz unifocal stimulation demonstrated only a non-significant trend toward inhibition ( p = 0.071). Effects were transient, most evident at 5- and 30 min post-TUS. Behavioral performance (measured via RT and task accuracy) remained unchanged across all conditions Significance. Findings suggest that spatial coverage, achieved through broader 250 kHz beams or multi-focal cycling, is critical for effective TUS-induced neuromodulation of the motor cortex. Future studies should optimize dosing and targeting strategies to balance precision and efficacy.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Motor CortexEvoked Potentials, MotorHumansMaleFemaleAdultDouble-Blind MethodYoung AdultTranscranial Magnetic StimulationReaction Time

Stichwörter der Autor:innen

corticospinal excitabilityfocal sizefundamental frequencymotor evoked potentialtranscranial ultrasound stimulation

Autor:innen und Institutionen

  • Department of Clinical Neurosciences, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada.
  • Hotchkiss Brain Institute, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada.
  • Department of Radiology, University of Calgary, Calgary, AB, Canada.
  • Department of Biomedical Engineering, University of Calgary, Calgary, AB, Canada.
  • Department of Radiology, Radio-oncology and Nuclear Medicine, Université de Montréal, Montréal, QC, Canada.
  • Centre de Recherche, Institut Universitaire de Gériatrie de Montréal, Montreal, QC, Canada.

ORCID-Profile: Ali K Zadeh, Davide Martino, G Bruce Pike, Samuel Pichardo, Oury Monchi

Förderung

  • Canada Foundation for Innovation
  • NSERC BRAIN CREATE
  • Natural Sciences and Engineering Research Council of Canada
  • Cumming Medical Research Fund

Zitieren

APA

Zadeh, A. K., Coreas, A., Shrestha, S., Kathol, I., Martino, D., Pike, G. B., Pichardo, S., & Monchi, O. (2026). Broad vs narrow focus: how frequency and focal size affect transcranial ultrasound stimulation in motor cortex. Journal of Neural Engineering, 23(3), 036031. https://doi.org/10.1088/1741-2552/ae730a

Vancouver

Zadeh AK, Coreas A, Shrestha S, Kathol I, Martino D, Pike GB, et al. Broad vs narrow focus: how frequency and focal size affect transcranial ultrasound stimulation in motor cortex. Journal of Neural Engineering. 2026;23(3):036031. doi:10.1088/1741-2552/ae730a

BibTeX
@article{Zadeh2026,
  author = {Zadeh, Ali K and Coreas, Alan and Shrestha, Shirshak and Kathol, Iris and Martino, Davide and Pike, G Bruce and Pichardo, Samuel and Monchi, Oury},
  title = {Broad vs narrow focus: how frequency and focal size affect transcranial ultrasound stimulation in motor cortex},
  journal = {Journal of Neural Engineering},
  year = {2026},
  volume = {23},
  number = {3},
  pages = {036031},
  doi = {10.1088/1741-2552/ae730a}
}
Kostenlos starten →