Maximizing the fidelity of a photovoltaic subretinal prosthesis for human patients
Journal of Neural Engineering · 2026
DOI: 10.1088/1741-2552/ae6d77 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Neural Engineering, 2026. Verfasst von Nathan Jensen und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical Engineering, Stanford University, Stanford, CA 94305, United States of America. Hauptthemen laut MEDLINE: Visual Prosthesis, Electrodes, Implanted, Retina, Prosthesis Design. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NEI NIH HHS, National Institutes of Health, U.S. Department of Defense.
Abstract (Originalsprache)
Objective. PRIMA subretinal implants provide prosthetic vision to patients blinded by age-related macular degeneration, with acuity closely matching the sampling limit of the pixel pitch: a single 100 μ m pixel per line of a letter corresponds to 20/420 acuity. Decreasing the pixel size in the same flat geometry is difficult due to the constrained electric field, especially considering a 40 μ m thick debris layer separating the implant from the target neurons. Here we optimize the electrode design to help overcome such limitations. Approach. An end-to-end modeling pipeline combines the retinal photovoltaic implant simulator based on the Xyce circuit simulator with an interface to COMSOL Multiphysics for electric field modelling. It was used to generate and characterize implants in an open-loop sampling-based optimization. Implant performance was evaluated with respect to voltage drop across bipolar cells (BC) (representing the stimulation strength), pattern contrast, and neural selectivity. Main results. The highest selectivity in stimulation of BCs was achieved with arrays having active electrodes on pillars and return electrodes connected in a mesh surrounding the photovoltaic pixels in the array. Such a design, even with pixels down to 20 μ m, provides stimulation strength exceeding, and contrast similar to that of flat 100 μ m PRIMA pixels. Significance. Using a novel 3D electrode design, the pitch of the photovoltaic array can be decreased to 20 μ m, while providing performance that exceeds the flat 100 μ m PRIMA pixels. In humans, 20 μ m resolution on the retina corresponds to a visual acuity of 20/80 – a five times improvement compared to the current clinical device.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Electrical Engineering, Stanford University, Stanford, CA 94305, United States of America.
- Department of Ophthalmology, Stanford University, Stanford, CA 94305, United States of America.
- Hansen Experimental Physics Laboratory, Stanford University, Stanford, CA 94305, United States of America.
- School of Life Sciences, EPFL, Lausanne, Switzerland.
ORCID-Profile: Nathan Jensen, Anna Kochnev Goldstein, Quentin Devaud, Daniel Palanker
Förderung
- NEI NIH HHS
- National Institutes of Health
- U.S. Department of Defense
Zitieren
APA
Jensen, N., Ly, K., Kochnev Goldstein, A., Devaud, Q., & Palanker, D. (2026). Maximizing the fidelity of a photovoltaic subretinal prosthesis for human patients. Journal of Neural Engineering. https://doi.org/10.1088/1741-2552/ae6d77
Vancouver
Jensen N, Ly K, Kochnev Goldstein A, Devaud Q, Palanker D. Maximizing the fidelity of a photovoltaic subretinal prosthesis for human patients. Journal of Neural Engineering. 2026. doi:10.1088/1741-2552/ae6d77
BibTeX
@article{Jensen2026,
author = {Jensen, Nathan and Ly, Keith and Kochnev Goldstein, Anna and Devaud, Quentin and Palanker, Daniel},
title = {Maximizing the fidelity of a photovoltaic subretinal prosthesis for human patients},
journal = {Journal of Neural Engineering},
year = {2026},
doi = {10.1088/1741-2552/ae6d77}
}
EUVIMED