EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Non-invasive somatotopic proprioceptive feedback for closed-loop robotic hand aperture control

Olivier Lecompte iD, Sofiane Achiche iD, Maria Haddad iD, Amandine Gesta iD, Abolfazl Mohebbi iD

Journal of Neural Engineering · 01.06.2026 · 23 (3) · 036019

DOI: 10.1088/1741-2552/ae6d76 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Neural Engineering, online erschienen am 26.05.2026. Verfasst von Olivier Lecompte und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, Polytechnique Montréal, Montréal, Qc, Canada. Hauptthemen laut MEDLINE: Proprioception, Feedback, Sensory, Robotics, Hand. Die Arbeit nennt 69 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Fonds de recherche du Québec – Nature et technologies.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective. Current robotic prostheses developed for individuals with transradial amputation often lack physiological feedback, particularly proprioceptive information, which limits control precision and increases reliance on vision. Approach. This study investigates the effect of introducing non-invasive somatotopic feedback using transcutaneous electrical nerve stimulation (TENS) to convey hand aperture information, as an artificial form of proprioceptive feedback. Twenty healthy participants with intact limbs were divided into two groups: one receiving TENS-based feedback and one without feedback. Participants performed an aperture control task under visual and non-visual conditions, with some trials including a concurrent Stroop task to assess cognitive load. We hypothesized that providing non-invasive somatotopic proprioceptive feedback via TENS mitigates key control and integration challenges, leading to improved accuracy, faster learning, and reduced reliance on vision, without increasing cognitive demands. Main results. Under visual deprivation, participants receiving TENS feedback achieved significantly smaller aperture control errors than those without feedback, both under alternating visual conditions ( p < 0.001 ) and under prolonged visual deprivation conditions ( p = 0.017 ). From the very first trial, TENS-based feedback enabled control accuracy comparable to that with visual input. Although perceptual shifts affected control accuracy under dual-task conditions, the +TENS group maintained high cognitive performance and effective control toward perceived functional targets, suggesting that the artificial feedback nonetheless supported hand control in the presence of a secondary task. Significance. These findings highlight the potential of non-invasive somatotopic proprioceptive feedback delivered through TENS to provide physiologically meaningful information and support future strategies for restoring proprioceptive function in prosthetic hand users.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ProprioceptionFeedback, SensoryRoboticsHandPsychomotor PerformanceTranscutaneous Electric Nerve StimulationArtificial LimbsHumansMaleFemaleAdultYoung Adult

Stichwörter der Autor:innen

artificial limbsnon-invasiveproprioceptive feedbackprostheticsrobotic hand controlsomatotopytranscutaneous electrical nerve stimulation

Autor:innen und Institutionen

  • Department of Mechanical Engineering, Polytechnique Montréal, Montréal, Qc, Canada.
  • Ph.D. program in Quantitative Life Sciences, Interfaculty Studies, McGill University, Montréal, Qc, Canada.

ORCID-Profile: Olivier Lecompte, Sofiane Achiche, Maria Haddad, Amandine Gesta, Abolfazl Mohebbi

Förderung

  • Fonds de recherche du Québec – Nature et technologies

Zitieren

APA

Lecompte, O., Achiche, S., Haddad, M., Gesta, A., & Mohebbi, A. (2026). Non-invasive somatotopic proprioceptive feedback for closed-loop robotic hand aperture control. Journal of Neural Engineering, 23(3), 036019. https://doi.org/10.1088/1741-2552/ae6d76

Vancouver

Lecompte O, Achiche S, Haddad M, Gesta A, Mohebbi A. Non-invasive somatotopic proprioceptive feedback for closed-loop robotic hand aperture control. Journal of Neural Engineering. 2026;23(3):036019. doi:10.1088/1741-2552/ae6d76

BibTeX
@article{Lecompte2026,
  author = {Lecompte, Olivier and Achiche, Sofiane and Haddad, Maria and Gesta, Amandine and Mohebbi, Abolfazl},
  title = {Non-invasive somatotopic proprioceptive feedback for closed-loop robotic hand aperture control},
  journal = {Journal of Neural Engineering},
  year = {2026},
  volume = {23},
  number = {3},
  pages = {036019},
  doi = {10.1088/1741-2552/ae6d76}
}
Kostenlos starten →