EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Extracting robust single-trial somatosensory evoked potentials for non-invasive brain computer interfaces

Disha Gupta iD, Jodi Brangaccio iD, Helia Mojtabavi, Jonathan Wolpaw iD, N Jeremy Hill iD

Journal of Neural Engineering · 2025

DOI: 10.1088/1741-2552/adfd8a ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Neural Engineering, 2025. Verfasst von Disha Gupta und 4 weiteren Autor:innen. Beteiligte Einrichtung: National Center for Adaptive Neurotechnology, Stratton Veterans Affairs Medical Center, Albany, NY 12208, United States of America. Hauptthemen laut MEDLINE: Brain-Computer Interfaces, Evoked Potentials, Somatosensory, Electroencephalography. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 123 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: RRD VA, NIBIB NIH HHS, National Institute of Biomedical Imaging and Bioengineering.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective. Reliable extraction of single-trial somatosensory evoked potentials (SEPs) is essential for developing brain-computer interface (BCI) applications to support rehabilitation after brain injury. For real-time feedback, these responses must be extracted prospectively on every trial, with minimal post-processing and artifact correction. However, noninvasive SEPs elicited by electrical stimulation at recommended parameter settings (0.1–0.2 msec pulse width, stimulation at or below motor threshold, 2–5 Hz frequency) are typically small and variable, often requiring averaging across multiple trials or extensive processing. Here, we describe and evaluate ways to optimize the stimulation setup to enhance the signal-to-noise ratio (SNR) of noninvasive single-trial SEPs, enabling more reliable extraction. Approach. SEPs were recorded with scalp electroencephalography in tibial nerve stimulation in thirteen healthy people, and two people with CNS injuries. Three stimulation frequencies (lower than recommended: 0.2 Hz, 1 Hz, 2 Hz) with a pulse width longer than recommended (1 msec), at a stimulation intensity based on H-reflex and M-wave at Soleus muscle were evaluated. Detectability of single-trial SEPs relative to background noise was tested offline and in a pseudo-online analysis, followed by a real-time demonstration. Main results. SEP N70 was observed predominantly at the central scalp regions. Online decoding performance was significantly higher with Laplacian filter. Generalization performance showed an expected degradation, at all frequencies, with an average decrease of 5.9% (multivariate) and 6.5% (univariate), with an AUC score ranging from 0.78–0.90. The difference across stimulation frequencies was not significant. In individuals with injuries, AUC of 0.86 (incomplete spinal cord injury) and 0.81 (stroke) was feasible. Real-time demonstration showed SEP detection with AUC of 0.89. Significance. This study describes and evaluates a system for extracting single-trial SEPs in real-time, suitable for a BCI-based operant conditioning. It enhances SNR of individual SEPs by alternate electrical stimulation parameters, dry headset, and optimized signal processing.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Brain-Computer InterfacesEvoked Potentials, SomatosensoryElectroencephalographyHumansMaleAdultFemaleYoung AdultElectric StimulationMiddle AgedSignal-To-Noise RatioTibial Nerve

Stichwörter der Autor:innen

brain computer interfacingsingle-trial decodingsomatosensory evoked potentialstibial nerve stimulation

Autor:innen und Institutionen

  • National Center for Adaptive Neurotechnology, Stratton Veterans Affairs Medical Center, Albany, NY 12208, United States of America.
  • Electrical and Computer Engineering, University of Albany, State University of NY, Albany, NY, United States of America.

ORCID-Profile: Disha Gupta, Jodi Brangaccio, Jonathan Wolpaw, N Jeremy Hill

Förderung

  • RRD VA
  • NIBIB NIH HHS
  • National Institute of Biomedical Imaging and Bioengineering
  • Stratton Veterans Affairs Medical Center- Albany
  • Spinal Cord Injury Research Board - NYSDOH

Zitieren

APA

Gupta, D., Brangaccio, J., Mojtabavi, H., Wolpaw, J., & Hill, N. J. (2025). Extracting robust single-trial somatosensory evoked potentials for non-invasive brain computer interfaces. Journal of Neural Engineering. https://doi.org/10.1088/1741-2552/adfd8a

Vancouver

Gupta D, Brangaccio J, Mojtabavi H, Wolpaw J, Hill NJ. Extracting robust single-trial somatosensory evoked potentials for non-invasive brain computer interfaces. Journal of Neural Engineering. 2025. doi:10.1088/1741-2552/adfd8a

BibTeX
@article{Gupta2025,
  author = {Gupta, Disha and Brangaccio, Jodi and Mojtabavi, Helia and Wolpaw, Jonathan and Hill, N Jeremy},
  title = {Extracting robust single-trial somatosensory evoked potentials for non-invasive brain computer interfaces},
  journal = {Journal of Neural Engineering},
  year = {2025},
  doi = {10.1088/1741-2552/adfd8a}
}
Kostenlos starten →