SSVEP-based BCI using ultra-low-frequency and high-frequency peripheral flickers
Journal of Neural Engineering · 01.06.2025 · 22 (3) · 036032
DOI: 10.1088/1741-2552/addf82 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Neural Engineering, online erschienen am 10.06.2025. Verfasst von Zexin Pang und 5 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Advanced Medical Materials and Devices, Institute of Biomedical Engineering, Tianjin Institutes of Health Science, Chinese Ac…. Hauptthemen laut MEDLINE: Brain-Computer Interfaces, Evoked Potentials, Visual, Photic Stimulation, Electroencephalography. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 33 Literaturangaben. Gefördert von: Non-profit Central Research Institute Fund of Chinese Academy of Medical Sciences, Tianjin Municipal Science and Technology Project, National Key Research and Development Program of China.
Abstract (Originalsprache)
Objective . existing steady-state visual evoked potential (SSVEP)-based brain–computer interface (BCI) systems predominantly employ a flicker frequency range of 8–20 Hz, which often induces visual fatigue in users, thereby compromising system performance. Considering that, this study introduces an innovative paradigm to enhance the user experience of SSVEP-based BCIs while maintaining the performance. Approach . the system encodes 12 targets by integrating ultra-low-frequency (2.00–3.32 Hz) and high-frequency (34.00–35.32 Hz) flickers with peripheral stimulation, and task-related component analysis is employed for SSVEP signal identification. Main results . the feasibility of the ultra-low-frequency peripheral stimulation paradigm was validated through online experiments, achieving an average accuracy of 89.03 ± 9.95% and an information transfer rate (ITR) of 66.74 ± 15.44 bits min −1 . For the high-frequency peripheral stimulation paradigm, only the stimulation frequency changed, the paradigm, the signal processing algorithm and the step of frequency and phase were unchanged. The online experiments demonstrated an average accuracy of 93.55 ± 3.02% and an ITR of 51.88 ± 3.74 bits min −1 . Significance . the performance of the proposed system has reached a relatively high level among the current user-friendly SSVEP-based BCI systems. This study successfully innovates the paradigm for SSVEP-based BCIs, offering new insights into the development of user-friendly systems that balance high performance and user comfort.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- State Key Laboratory of Advanced Medical Materials and Devices, Institute of Biomedical Engineering, Tianjin Institutes of Health Science, Chinese Academy of Medical Science and Peking Union Medical College, Tianjin, Pe…
- Tianjin Key Laboratory of Neuromodulation and Neurorepair, Institute of Biomedical Engineering, Chinese Academy of Medical Sciences and Peking Union Medical College, Tianjin, People's Republic of China.
ORCID-Profile: Xiaogang Chen
Förderung
- Non-profit Central Research Institute Fund of Chinese Academy of Medical Sciences
- Tianjin Municipal Science and Technology Project
- National Key Research and Development Program of China
- National Natural Science Foundation of China
Zitieren
APA
Pang, Z., Zhang, R., Li, M., Li, Z., Cui, H., & Chen, X. (2025). SSVEP-based BCI using ultra-low-frequency and high-frequency peripheral flickers. Journal of Neural Engineering, 22(3), 036032. https://doi.org/10.1088/1741-2552/addf82
Vancouver
Pang Z, Zhang R, Li M, Li Z, Cui H, Chen X. SSVEP-based BCI using ultra-low-frequency and high-frequency peripheral flickers. Journal of Neural Engineering. 2025;22(3):036032. doi:10.1088/1741-2552/addf82
BibTeX
@article{Pang2025,
author = {Pang, Zexin and Zhang, Ruoqing and Li, Meng and Li, Zhaohui and Cui, Hongyan and Chen, Xiaogang},
title = {SSVEP-based BCI using ultra-low-frequency and high-frequency peripheral flickers},
journal = {Journal of Neural Engineering},
year = {2025},
volume = {22},
number = {3},
pages = {036032},
doi = {10.1088/1741-2552/addf82}
}
EUVIMED