EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Enhancing transcranial ultrasound stimulation planning with MRI-derived skull masks: a comparative analysis with CT-based processing

Ali K Zadeh iD, Oula Puonti, Björn Sigurðsson, Axel Thielscher, Oury Monchi, Samuel Pichardo iD

Journal of Neural Engineering · 2025

DOI: 10.1088/1741-2552/adab22 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Neural Engineering, 2025. Verfasst von Ali K Zadeh und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Neurosciences, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada. Hauptthemen laut MEDLINE: Skull, Magnetic Resonance Imaging, Tomography, X-Ray Computed. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: BRAIN CREATE, Lundbeck Foundation, Innovationsfonden.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective. Transcranial ultrasound stimulation (TUS) presents challenges in ultrasound wave transmission through the skull, affecting study outcomes due to aberration and attenuation. While planning strategies incorporating 3D computed tomography (CT) scans help mitigate these issues, they expose participants to radiation, which can raise ethical concerns. A solution involves generating skull masks from participants’ anatomical magnetic resonance imaging (MRI). This study aims to compare ultrasound field predictions between CT-derived and MRI-derived skull masks in TUS planning. Approach. Five participants with a range of skull density ratios (SDRs: 0.31, 0.42, 0.55, 0.67, and 0.79) were selected, each having both CT and T1/T2-weighted MRI scans. Ultrasound simulations were performed using BabelBrain software with a single-element transducer (diameter = 50 mm, F # = 1) at 250, 500, and 750 kHz frequencies. CT scans were used to generate maps of the skull’s acoustic properties. The MRI scans were processed using the Charm segmentation tool from the SimNIBS tool suite using default and custom settings adapted for better skull segmentation. Ultrasound was adjusted to target 30 mm below the skull’s surface at 54 electroencephalogram (EEG) locations. Main Results. The custom setting in Charm significantly improved the Dice coefficient between MRI- and CT-derived masks when compared to the default setting ( p < 0.001). The maximum pressure error significantly decreased in the custom setting compared to the default setting ( p < 0.001). Additionally, the focus location error median across different SDRs averaged 2.32, 1.45, and 1.57 mm in default and 2.08, 1.38, and 1.44 mm in custom conditions for 250 kHz, 500 kHz, and 750 kHz respectively. Significance. MRI-derived skull masks offer satisfactory accuracy at many EEG sites, and using custom settings can further enhance this accuracy. However, significant errors at specific locations highlight the importance of carefully considering stimulation location when choosing between CT- and MRI-derived skull modeling.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SkullMagnetic Resonance ImagingTomography, X-Ray ComputedHumansMaleFemaleAdultBrain

Stichwörter der Autor:innen

computed tomographymagnetic resonance imagingskull modelingtranscranial ultrasound stimulation

Autor:innen und Institutionen

  • Department of Clinical Neurosciences, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada.
  • Hotchkiss Brain Institute, Cumming School of Medicine, University of Calgary, Calgary, AB, Canada.
  • Danish Research Centre for Magnetic Resonance, Centre for Functional and Diagnostic Imaging and Research, Copenhagen University Hospital-Amager and Hvidovre, Copenhagen, Denmark.
  • Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Boston, MA, United States of America.
  • Section for Magnetic Resonance, DTU Health Tech, Technical University of Denmark, Kgs Lyngby, Denmark.
  • Department of Radiology, University of Calgary, Calgary, AB, Canada.

ORCID-Profile: Ali K Zadeh, Samuel Pichardo

Förderung

  • BRAIN CREATE
  • Lundbeck Foundation
  • Innovationsfonden
  • Canada Foundation for Innovation
  • European Union
  • Natural Sciences and Engineering Research Council of Canada

Zitieren

APA

Zadeh, A. K., Puonti, O., Sigurðsson, B., Thielscher, A., Monchi, O., & Pichardo, S. (2025). Enhancing transcranial ultrasound stimulation planning with MRI-derived skull masks: a comparative analysis with CT-based processing. Journal of Neural Engineering. https://doi.org/10.1088/1741-2552/adab22

Vancouver

Zadeh AK, Puonti O, Sigurðsson B, Thielscher A, Monchi O, Pichardo S. Enhancing transcranial ultrasound stimulation planning with MRI-derived skull masks: a comparative analysis with CT-based processing. Journal of Neural Engineering. 2025. doi:10.1088/1741-2552/adab22

BibTeX
@article{Zadeh2025,
  author = {Zadeh, Ali K and Puonti, Oula and Sigurðsson, Björn and Thielscher, Axel and Monchi, Oury and Pichardo, Samuel},
  title = {Enhancing transcranial ultrasound stimulation planning with MRI-derived skull masks: a comparative analysis with CT-based processing},
  journal = {Journal of Neural Engineering},
  year = {2025},
  doi = {10.1088/1741-2552/adab22}
}
Kostenlos starten →