Calibrating Self-weighted Shear Estimation via Field Distortion
Research in Astronomy and Astrophysics · 01.01.2027 · 27 (1) · 015014
DOI: 10.1088/1674-4527/aea100 ↗Kurz gefasst
Fachartikel in der Zeitschrift Research in Astronomy and Astrophysics, online erschienen am 06.11.2026. Verfasst von Zhenjie Liu und 3 weiteren Autor:innen. Die Arbeit nennt 41 Literaturangaben.
Abstract (Originalsprache)
Accurate cosmic shear measurement is the key to fully realize the scientific potential of large scale galaxy surveys. The Fourier_Quad (FQ) shear measurement method has been significantly developed to avoid biases caused by various factors, including the point-spread function (PSF), photon noise, pixelation effect, selection effects, etc. Shear statistics have also been optimized using the PDF-SYM method (symmetrization of the Probability Distribution Function of the shear estimators) to achieve the minimal statistical error, without introducing systematic error. Nevertheless, the iterative nature of the PDF-SYM method makes it computationally expensive for massive datasets. To improve computational efficiency, we introduce the self-weighted shear estimation (SWSE) method, which employs a specific self-weighting scheme to naturally suppress the shape noise as well as to balance the contributions from the bright and faint galaxies. Because SWSE is intrinsically biased, the primary focus of this work is to robustly evaluate whether the field-distortion test (FD test, a way to calibrate the shear bias on real data) can accurately recover and correct these inherent multiplicative and additive biases. Using both simulated and real survey data, we demonstrate that the FD test can successfully calibrate SWSE for galaxy–galaxy lensing measurements, while computational benchmarks show a reduction in shear-estimation time by factors of approximately 40–200 relative to PDF-SYM. After calibration, SWSE achieves statistical precision consistent with that of PDF-SYM within the uncertainties examined in this work. Our results demonstrate the potential of combining the FD test with SWSE as a computationally efficient framework for forthcoming large-scale weak-lensing surveys.
Zitieren
APA
Liu, Z., Sun, J., Zhang, J., & Liu, C. (2027). Calibrating Self-weighted Shear Estimation via Field Distortion. Research in Astronomy and Astrophysics, 27(1), 015014. https://doi.org/10.1088/1674-4527/aea100
Vancouver
Liu Z, Sun J, Zhang J, Liu C. Calibrating Self-weighted Shear Estimation via Field Distortion. Research in Astronomy and Astrophysics. 2027;27(1):015014. doi:10.1088/1674-4527/aea100
BibTeX
@article{Liu2027,
author = {Liu, Zhenjie and Sun, Jiarui and Zhang, Jun and Liu, Cong},
title = {Calibrating Self-weighted Shear Estimation via Field Distortion},
journal = {Research in Astronomy and Astrophysics},
year = {2027},
volume = {27},
number = {1},
pages = {015014},
doi = {10.1088/1674-4527/aea100}
}
EUVIMED