EUVIMEDEUVIMED entdecken
Crossref

Pressure measurement based on continuous-amplitude-scanned wavelength modulation spectroscopy

Haodong Chen, Youquan Yang, Shibo Lin, Zhimin Peng, Yanjun Ding, Yanjun Du

Chinese Physics B · 05.08.2026

DOI: 10.1088/1674-1056/ae9532 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Chinese Physics B, online erschienen am 05.08.2026. Verfasst von Haodong Chen und 5 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Pressure is a key parameter in industrial processes, environmental monitoring, and combustion diagnostics. Tunable diode laser absorption spectroscopy (TDLAS) provides a non-contact approach for pressure measurement owing to its fast response and remote sensing capability. However, pressure measurement based on direct absorption spectroscopy (DAS) is susceptible to laser intensity noise and baseline fitting errors. And conventional wavelength modulation spectroscopy (WMS) methods often rely on complex models and are sensitive to harmonic feature extraction, especially when measuring over a large pressure range. To address these issues, a high-accuracy non-contact pressure measurement method based on continuous-amplitude-scanned WMS is proposed. In this method, a sawtooth-wave amplitude scan is superimposed on the sinusoidal modulation of the laser current. The relationship between the second-harmonic amplitude and the modulation amplitude is obtained through harmonic analysis, and the peak modulation amplitude is used as the characteristic parameter for pressure retrieval. A typical H 2 O absorption line at 7181.1577 cm -1 is selected to validate the performance of the proposed method. Simulation and experimental results show that precise pressure can be achieved when the modulation-to-scan frequency ratio is over 80. Experimental measurements further demonstrate that the proposed method enables high-accuracy pressure retrieval in the range of 20–100 kPa. The retrieved pressure exhibits a good linear relationship with the reference pressure, with R 2 > 0.9982, and the mean absolute error at different pressure points is less than 1.31 kPa. Long-term continuous measurements show that the mean deviation of the retrieved pressure is within 0.5 kPa, and the standard deviation of pressure fluctuation is approximately 1 kPa, indicating a good stability for pressure measurement. These results suggest that continuous-amplitude-scanned WMS is a feasible approach for high-accuracy non-contact TDLAS-based pressure retrieval over a broad pressure range.

Zitieren

APA

Chen, H., Yang, Y., Lin, S., Peng, Z., Ding, Y., & Du, Y. (2026). Pressure measurement based on continuous-amplitude-scanned wavelength modulation spectroscopy. Chinese Physics B. https://doi.org/10.1088/1674-1056/ae9532

Vancouver

Chen H, Yang Y, Lin S, Peng Z, Ding Y, Du Y. Pressure measurement based on continuous-amplitude-scanned wavelength modulation spectroscopy. Chinese Physics B. 2026. doi:10.1088/1674-1056/ae9532

BibTeX
@article{Chen2026,
  author = {Chen, Haodong and Yang, Youquan and Lin, Shibo and Peng, Zhimin and Ding, Yanjun and Du, Yanjun},
  title = {Pressure measurement based on continuous-amplitude-scanned wavelength modulation spectroscopy},
  journal = {Chinese Physics B},
  year = {2026},
  doi = {10.1088/1674-1056/ae9532}
}
Kostenlos starten →