Evaluation of the electric quadrupole shift in the ytterbium single-ion optical clock
Chinese Physics B · 01.10.2026 · 35 (10) · 103201
DOI: 10.1088/1674-1056/ae60eb ↗Kurz gefasst
Fachartikel in der Zeitschrift Chinese Physics B, erschienen am 01.10.2026. Verfasst von Chao-Wei 潮巍 Wang 王 und 6 weiteren Autor:innen. Die Arbeit nennt 37 Literaturangaben.
Abstract (Originalsprache)
Optical clocks with ultralow uncertainty are strong candidates for the next redefinition of the SI second. The 171 Yb + single-ion clock is particularly attractive owing to its two clock transitions (E2 and E3) and its potential for low uncertainty. A major contribution to the uncertainty budget arises from the electric-quadrupole shift, caused by the interaction between the atomic quadrupole moment and the electric-field gradient at the trap center and strongly dependent on the orientation of the quantization axis. To evaluate this shift, a simplified orthogonal magnetic-field method was employed: three mutually orthogonal magnetic-field directions are generated together with an auxiliary non-orthogonal field. With a dual-condition locking scheme, we measure the E2 transition frequency differences between magnetic-field configurations, infer the electric-field gradient, and apply corrections for the associated quadratic Zeeman shifts. The uncertainty due to magnetic-field misalignment is quantified using a calibrated current-to-field model. The resulting electric-quadrupole shift correction for the 2 S 1/2 → 2 F 7/2 (E3) transition is 3.24 mHz, corresponding to a fractional uncertainty of 1.1×10 −18 in the absolute frequency measurement.
Zitieren
APA
王, C. 潮. W., 戴, S. 少. D., 左, Y. 娅. Z., 刘, K. 昆. L., 赵, W. 文. Z., 韩, Y. 越. H., & 房, F. 芳. F. (2026). Evaluation of the electric quadrupole shift in the ytterbium single-ion optical clock. Chinese Physics B, 35(10), 103201. https://doi.org/10.1088/1674-1056/ae60eb
Vancouver
王 C潮W, 戴 S少D, 左 Y娅Z, 刘 K昆L, 赵 W文Z, 韩 Y越H, et al. Evaluation of the electric quadrupole shift in the ytterbium single-ion optical clock. Chinese Physics B. 2026;35(10):103201. doi:10.1088/1674-1056/ae60eb
BibTeX
@article{2026,
author = {王, Chao-Wei 潮巍 Wang and 戴, Shao-Yang 少阳 Dai and 左, Ya-Ni 娅妮 Zuo and 刘, Kun 昆 Liu and 赵, Wen-Bo 文博 Zhao and 韩, Yue-Xiang 越祥 Han and 房, Fang 芳 Fang},
title = {Evaluation of the electric quadrupole shift in the ytterbium single-ion optical clock},
journal = {Chinese Physics B},
year = {2026},
volume = {35},
number = {10},
pages = {103201},
doi = {10.1088/1674-1056/ae60eb}
}
EUVIMED