Micro-trench measurement of selective boron deposition during boron powder dropper operation in DIII-D
Physica Scripta · 13.11.2026 · 101 (45) · 455602
DOI: 10.1088/1402-4896/aebac5 ↗Kurz gefasst
Fachartikel in der Zeitschrift Physica Scripta, online erschienen am 10.11.2026. Verfasst von Shota Abe und 10 weiteren Autor:innen. Die Arbeit nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: DOE Office of Science, U.S. Department of Energy, Office of Science, Office of Fusion Energy Sciences, U.S. Department of Energy, Office of Science/Fusion Energy Sciences.
Abstract (Originalsprache)
The selective boron (B) deposition rate is reported as measured using the micro-trench method in the DIII-D divertor during deuterium (D) H-mode outer strike point (OSP) sweeping plasma discharges with B powder injection via the impurity powder dropper (IPD). The selective deposition is defined as a result of B deposition and impurity sputtering (deposited B sputtered by B ions or other impurity ion species) in a micro-scale region geometrically shadowed from direct fuel/D + ion bombardment. To perform this work, micro-trenches 32 μ m × 32 μ m × 4 μ m deep were fabricated on a single-crystal silicon sample. The sample was exposed to DIII-D H-mode ‘cleaning’ plasma discharges with D fueling and OSP sweeping via the divertor material evaluation system (DiMES). The IPD injected B powder at rates of 5–20 mg s −1 during 2–5 s of H-mode plasmas in multiple discharges, adding up to 0.4 g injected in total. Injected B powders were ablated, ionized, and transported to PFC surfaces. Post-mortem analysis revealed that impurity deposition concentrated in a D + ion shadowed area on the micro-trench floor, while no B deposition was observed outside of the micro-trench, which implied that net impurity deposition can be significantly enhanced by rough micro-structures on PFC surfaces, i.e. selective deposition. An energy-dispersive X-ray spectroscopy (EDS) analysis detected impurity deposition containing B, carbon, oxygen, and silicon. Combining the impurity deposition height profile measured by atomic force microscopy and the relative B concentration profiles measured by EDS, we determined the selective B deposition thickness of ∼25 nm in the diverter region. The measured B deposition thickness agreed with a mass balance analysis to within half the magnitude when the B impurity flux was assumed to be concentrated near the OSP, as predicted by a real-time wall conditioning model developed to optimize IPD operations of advanced fusion reactors.
Förderung
- DOE Office of Science
- U.S. Department of Energy, Office of Science, Office of Fusion Energy Sciences
- U.S. Department of Energy, Office of Science/Fusion Energy Sciences
Zitieren
APA
Abe, S., Effenberg, F., Bortolon, A., Bykov, I., Ren, J., Rudakov, D. L., McLean, A. G., Hood, R., Barr, J. L., Hyatt, A. W., & Abrams, T. (2026). Micro-trench measurement of selective boron deposition during boron powder dropper operation in DIII-D. Physica Scripta, 101(45), 455602. https://doi.org/10.1088/1402-4896/aebac5
Vancouver
Abe S, Effenberg F, Bortolon A, Bykov I, Ren J, Rudakov DL, et al. Micro-trench measurement of selective boron deposition during boron powder dropper operation in DIII-D. Physica Scripta. 2026;101(45):455602. doi:10.1088/1402-4896/aebac5
BibTeX
@article{Abe2026,
author = {Abe, Shota and Effenberg, Florian and Bortolon, Alessandro and Bykov, Igor and Ren, Jun and Rudakov, Dmitry L and McLean, Adam G and Hood, Ryan and Barr, Jayson L and Hyatt, Alan W and Abrams, Tyler},
title = {Micro-trench measurement of selective boron deposition during boron powder dropper operation in DIII-D},
journal = {Physica Scripta},
year = {2026},
volume = {101},
number = {45},
pages = {455602},
doi = {10.1088/1402-4896/aebac5}
}
EUVIMED