Compact low-power hardware design for real-time ECG signal pre-processing based on the Pan–Tompkins algorithm
Physica Scripta · 24.07.2026 · 101 (29) · 295003
DOI: 10.1088/1402-4896/ae8ac2 ↗Kurz gefasst
Fachartikel in der Zeitschrift Physica Scripta, online erschienen am 22.07.2026. Verfasst von Anuraj V und 2 weiteren Autor:innen. Die Arbeit nennt 27 Literaturangaben.
Abstract (Originalsprache)
In this work, Electrocardiogram (ECG) QRS complex detection is presented using the Pan–Tompkins algorithm with emphasis on hardware efficient real-time signal pre-processing. Two architectures are proposed, an finite state machine (FSM)-based reusable multiply and accumulate (MAC) architecture optimized for low-power and area-efficient ASIC implementation and a parallel MAC architecture targeting high-speed FPGA applications. Both architectures implement the complete Pan–Tompkins processing chain including band-pass filtering, differentiation, squaring, moving window integration (MWI) along with hardware-based thresholding and QRS detection using signed 18-bit fixed-point arithmetic with 9 fractional bits, 360 Hz ECG samples format. Synthesized on 90 nm and 45 nm GPDK libraries, the FSM-based reusable MAC architecture achieves reduction in ASIC area, power and power-delay product (PDP) by over 60%, while FPGA results show a 35% PDP improvement with reduced resource utilization and delay. Although a complete hardware-based QRS detection chain is implemented and evaluated for performance metrics, achieving clinically reliable detection accuracy using fixed-point hardware thresholding remains challenging. Therefore, to achieve clinically reliable detection accuracy, a hybrid evaluation framework is adopted in which hardware-generated MWI output is used for QRS detection in software using thresholding, refractory logic and search-back mechanisms. By using this hybrid approach evaluation on the MIT–BIH arrhythmia database achieves an average QRS detection accuracy of 98.26%.
Zitieren
APA
V, A., Sinha, N., & Vaithiyanathan, D. (2026). Compact low-power hardware design for real-time ECG signal pre-processing based on the Pan–Tompkins algorithm. Physica Scripta, 101(29), 295003. https://doi.org/10.1088/1402-4896/ae8ac2
Vancouver
V A, Sinha N, Vaithiyanathan D. Compact low-power hardware design for real-time ECG signal pre-processing based on the Pan–Tompkins algorithm. Physica Scripta. 2026;101(29):295003. doi:10.1088/1402-4896/ae8ac2
BibTeX
@article{V2026,
author = {V, Anuraj and Sinha, Neeraj and Vaithiyanathan, Dhandapani},
title = {Compact low-power hardware design for real-time ECG signal pre-processing based on the Pan–Tompkins algorithm},
journal = {Physica Scripta},
year = {2026},
volume = {101},
number = {29},
pages = {295003},
doi = {10.1088/1402-4896/ae8ac2}
}
EUVIMED