Plasma radiation simulation and tomographic reconstruction methods for multi-array bolometer system design on the MT-I spherical tokamak
Physica Scripta · 03.07.2026 · 101 (26) · 265602
DOI: 10.1088/1402-4896/ae7e61 ↗Kurz gefasst
Fachartikel in der Zeitschrift Physica Scripta, online erschienen am 29.06.2026. Verfasst von Azam Hussain und 3 weiteren Autor:innen. Die Arbeit nennt 37 Literaturangaben.
Abstract (Originalsprache)
Radiative losses from impurity species play a decisive role in determining the energy balance, performance and stability in fusion plasma devices. This article presents a comprehensive end-to-end simulation framework for the preliminary design of a multi-array Absolute Extreme Ultraviolet (AXUV) photodiode bolometry system for the MT-I spherical tokamak. The proposed configuration employs 48 viewing chords distributed across three poloidal arrays at ±45° and 90°, providing enhanced spatial coverage for elongated plasma geometries. The framework integrates impurity radiation modeling based on ADAS coronal equilibrium cooling coefficients for carbon, oxygen, and iron with a forward diagnostic model incorporating line-of-sight integration, etendue-based signal estimation, and detector response characteristics. Tomographic reconstruction is performed using minimum fisher information regularization (MFR) and Phillips–Tikhonov regularization (PTR). Under 3% Gaussian noise, a conservative lower bound for realistic AXUV system uncertainties, both methods achieve stable and comparable accuracy; however, MFR demonstrates improved preservation of edge gradients, while PTR yields smoother and more robust solutions in noise-affected regions. Reconstruction fidelity is significantly enhanced by multi-angle coverage, reducing the root-mean-square error from approximately 18% in two-array configurations to approximately 11%–12% with three arrays. Regularization parameters are optimized using L-curve analysis and the discrepancy principle, with the latter showing greater reliability for sparse-view conditions. This evaluated framework provides quantitative guidance for diagnostic design and establishes a reliable basis for radiant emission coefficient reconstruction and data interpretation in spherical tokamaks and other compact fusion devices.
Zitieren
APA
Hussain, A., Mian, A. Y., Gulfam, S., & Ahmad, Z. (2026). Plasma radiation simulation and tomographic reconstruction methods for multi-array bolometer system design on the MT-I spherical tokamak. Physica Scripta, 101(26), 265602. https://doi.org/10.1088/1402-4896/ae7e61
Vancouver
Hussain A, Mian AY, Gulfam S, Ahmad Z. Plasma radiation simulation and tomographic reconstruction methods for multi-array bolometer system design on the MT-I spherical tokamak. Physica Scripta. 2026;101(26):265602. doi:10.1088/1402-4896/ae7e61
BibTeX
@article{Hussain2026,
author = {Hussain, Azam and Mian, Asad Yaqoob and Gulfam, Saira and Ahmad, Zahoor},
title = {Plasma radiation simulation and tomographic reconstruction methods for multi-array bolometer system design on the MT-I spherical tokamak},
journal = {Physica Scripta},
year = {2026},
volume = {101},
number = {26},
pages = {265602},
doi = {10.1088/1402-4896/ae7e61}
}
EUVIMED