Optimization of synchrotron radiation inline phase contrast imaging based on a lens-coupled detector
Physica Scripta · 29.05.2026 · 101 (21) · 215002
DOI: 10.1088/1402-4896/ae6bc9 ↗Kurz gefasst
Fachartikel in der Zeitschrift Physica Scripta, online erschienen am 22.05.2026. Verfasst von Qiru Yi und 4 weiteren Autor:innen. Die Arbeit nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China, National Key Research and Development Program of China.
Abstract (Originalsprache)
Synchrotron radiation-based in-line phase contrast imaging technology has attracted significant attention due to its high sensitivity for imaging low-Z biological soft tissues. However, the synergistic effects of x-ray source size and lens-coupled detector point spread function (PSF) on imaging quality remain systematically unexplored. This study combines multi-scale simulations with synchrotron experiments to elucidate the dynamic modulation mechanisms governing the edge contrast of poly(methyl methacrylate) (PMMA) micro-spheres under varying source sizes (50–400 μm), specimen-detector distances (0–5000 mm), and detector PSF. Numerical simulations reveal that increasing source size from 50 μm to 400 μm induces geometric projection broadening, significantly degrading spatial resolution by up to 50%, while detector PSF dominates contrast loss in short-distance imaging. Experimental validation demonstrates that optimizing horizontal source dimension (350 μm→50 μm) enhances boundary contrast from 0.1 to 0.45 while effectively delaying phase blurring phenomena. The proposed framework systematically optimizes propagation-based inline phase-contrast imaging conditions by incorporating sample feature dimensions, accounting for variations in the extended source point spread function (PSF), and simulating the overall detector PSF for different scintillator configurations. These findings establish a quantifiable optimization framework for in situ high-resolution characterization of complex soft tissue architectures in biomedical imaging, advancing the practical implementation of synchrotron phase contrast imaging technology.
Förderung
- National Natural Science Foundation of China
- National Key Research and Development Program of China
Zitieren
APA
Yi, Q., Zhang, J., Wang, Y., Gang, L., & Jiang, X. (2026). Optimization of synchrotron radiation inline phase contrast imaging based on a lens-coupled detector. Physica Scripta, 101(21), 215002. https://doi.org/10.1088/1402-4896/ae6bc9
Vancouver
Yi Q, Zhang J, Wang Y, Gang L, Jiang X. Optimization of synchrotron radiation inline phase contrast imaging based on a lens-coupled detector. Physica Scripta. 2026;101(21):215002. doi:10.1088/1402-4896/ae6bc9
BibTeX
@article{Yi2026,
author = {Yi, Qiru and Zhang, Jie and Wang, Yanping and Gang, Li and Jiang, Xiaoming},
title = {Optimization of synchrotron radiation inline phase contrast imaging based on a lens-coupled detector},
journal = {Physica Scripta},
year = {2026},
volume = {101},
number = {21},
pages = {215002},
doi = {10.1088/1402-4896/ae6bc9}
}
EUVIMED