EUVIMEDEUVIMED entdecken
Crossref

Computational investigation of non-newtonian physiological flow and slip boundary effects on biofilm-inhibitory TPMS scaffold design

Khemraj Deshmukh, Anuj Rohatgi, Jitendra Kumar, Bratajit Basu, Siddhita Saini, Harshita Khatri, Nitesh Kumar Singh

Physica Scripta · 29.05.2026 · 101 (21) · 215009

DOI: 10.1088/1402-4896/ae6bc2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physica Scripta, online erschienen am 28.05.2026. Verfasst von Khemraj Deshmukh und 6 weiteren Autor:innen. Die Arbeit nennt 99 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study presents a computational rheology approach to assess the impact of scaffold shape and fluid dynamics on biofilm suppression. CFD simulations used COMSOL Multiphysics 5.6, which included laminar flow, solid mechanics, and FSI modules, and the studies were conducted on 12 scaffold architectures, comprising solid scaffolds (10% porosity) and TPMS-based IWP scaffolds (50% and 70% porosity). Six inlet velocity profiles sinusoidal and physiological were utilized to evaluate axial velocity, pressure, shear rate, stress, strain tensor, strain principal, deformation gradient and displacement gradient under slip wall boundary conditions for both Newtonian and non-Newtonian fluid types. Data from 12 observation stations for a duration of 1.0 s (step of 0.1 s) exhibited significant variations: non-Newtonian fluid type under physiological flow had shown more biofilm-antagonistic responses, where a peak wall pressure of the orders of 10 4 Pa with peak shear rate of the orders of 4000–5000 s −1 for core channel regions were observed with micro-scale deformations suggesting suitability of non-Newtonian fluid suitability under physiological flow for elimination of biofilm growth onto the scaffolds. The findings marked the important observation of fluid rheology associated with solids that might interplay in controlling and preventing the implant-associated infections in patients.

Zitieren

APA

Deshmukh, K., Rohatgi, A., Kumar, J., Basu, B., Saini, S., Khatri, H., & Singh, N. K. (2026). Computational investigation of non-newtonian physiological flow and slip boundary effects on biofilm-inhibitory TPMS scaffold design. Physica Scripta, 101(21), 215009. https://doi.org/10.1088/1402-4896/ae6bc2

Vancouver

Deshmukh K, Rohatgi A, Kumar J, Basu B, Saini S, Khatri H, et al. Computational investigation of non-newtonian physiological flow and slip boundary effects on biofilm-inhibitory TPMS scaffold design. Physica Scripta. 2026;101(21):215009. doi:10.1088/1402-4896/ae6bc2

BibTeX
@article{Deshmukh2026,
  author = {Deshmukh, Khemraj and Rohatgi, Anuj and Kumar, Jitendra and Basu, Bratajit and Saini, Siddhita and Khatri, Harshita and Singh, Nitesh Kumar},
  title = {Computational investigation of non-newtonian physiological flow and slip boundary effects on biofilm-inhibitory TPMS scaffold design},
  journal = {Physica Scripta},
  year = {2026},
  volume = {101},
  number = {21},
  pages = {215009},
  doi = {10.1088/1402-4896/ae6bc2}
}
Kostenlos starten →