EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Experimental and Monte Carlo evaluation of a GAGG-BGO phoswich detector using 3D-printed Tc-99m FLUX phantoms

Nuray Yavuzkanat, Vakkas Bozkurt, Taylan Yetkin, Sezgin Aydın, Sefa Erturk

Physica Scripta · 27.03.2026 · 101 (12) · 125303

DOI: 10.1088/1402-4896/ae5091 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physica Scripta, online erschienen am 23.03.2026. Verfasst von Nuray Yavuzkanat und 4 weiteren Autor:innen. Die Arbeit nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Scientific and Technological Research Council of Türkiye (TÜBITAK) 1001.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study presents an experimental and Monte Carlo-based evaluation of a compact GAGG(Ce)-BGO phoswich detector for detector-level Tc-99m imaging. Single-projection measurements obtained with a 4 × 4 detector module demonstrated that simple geometric structures from a 3D-printed phantom can be clearly resolved under collimated acquisition. Experimental images show good qualitative agreement with GATE-based simulations, confirming that the observed image features are primarily governed by detector configuration and source geometry. Spatial resolution analysis yields an intrinsic resolution of 4.3 mm from simulated point-source PSF/LSF and an effective image-based resolution of 5.9 mm derived from ESF/LSF analysis, reflecting additional blurring contributions inherent to image-based measurements. Geant4 simulations indicate a GAGG-to-BGO light output ratio of approximately five, consistent with experimental characterization and GATE-based image mapping. Compared to a reference NaI(Tl) detector, the phoswich configuration exhibits reduced background noise and improved signal-to-noise and contrast-to-noise ratios, highlighting its potential for scalable SPECT detector applications. The validated experimental–simulation framework provides a basis for future detector performance optimization, including depth-of-interaction–assisted image reconstruction and image quality enhancement through alternative collimator geometries and materials.

Förderung

  • Scientific and Technological Research Council of Türkiye (TÜBITAK) 1001

Zitieren

APA

Yavuzkanat, N., Bozkurt, V., Yetkin, T., Aydın, S., & Erturk, S. (2026). Experimental and Monte Carlo evaluation of a GAGG-BGO phoswich detector using 3D-printed Tc-99m FLUX phantoms. Physica Scripta, 101(12), 125303. https://doi.org/10.1088/1402-4896/ae5091

Vancouver

Yavuzkanat N, Bozkurt V, Yetkin T, Aydın S, Erturk S. Experimental and Monte Carlo evaluation of a GAGG-BGO phoswich detector using 3D-printed Tc-99m FLUX phantoms. Physica Scripta. 2026;101(12):125303. doi:10.1088/1402-4896/ae5091

BibTeX
@article{Yavuzkanat2026,
  author = {Yavuzkanat, Nuray and Bozkurt, Vakkas and Yetkin, Taylan and Aydın, Sezgin and Erturk, Sefa},
  title = {Experimental and Monte Carlo evaluation of a GAGG-BGO phoswich detector using 3D-printed Tc-99m FLUX phantoms},
  journal = {Physica Scripta},
  year = {2026},
  volume = {101},
  number = {12},
  pages = {125303},
  doi = {10.1088/1402-4896/ae5091}
}
Kostenlos starten →