100% humidity independent PTR-MS: Novel method and proof-of-concept *

Klaus Winkler, Rene Gutmann, Andreas Mauracher, Bea Rosenkranz, Lukas Märk, Philipp Sulzer

Physica Scripta · 01.12.2024 · 99 (12) · 121502

DOI: 10.1088/1402-4896/ad9362 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Physica Scripta, online erschienen am 27.11.2024. Verfasst von Klaus Winkler und 5 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 25 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

It has been well-known and studied that the quantification of various compounds with Proton-Transfer-Reaction—Mass Spectrometry (PTR-MS) is dependent on the sample gas humidity. For example, if the formaldehyde concentration in outdoor air remains constant, but the weather and thus the humidity changes, the measured signal intensity for protonated formaldehyde will change. Established countermeasures against this effect include labor-intensive calibrations at different humidity levels and subsequent data correction, the use of filters or membranes to dry the sample air, which will also trap analytes of interest, and the introduction of excessive amounts of humidity into the PTR reaction region to reduce the relative but not the absolute humidity changes caused by the sample gas, which alters the well-defined ion chemistry and again limits quantification accuracy. Here, we present a novel solution to the humidity dependence problem that comes virtually without any drawbacks, does not require any additional labor by the user, and does not diminish analytes of condensable nature. A target humidity for the PTR reaction region is chosen before the actual measurement. Via the controlled injection of water vapor into the reaction region, the humidity is kept constant throughout the analysis, independent of the sample gas constitution. Therefore, it can be excluded that any changes in the acquired ion signal intensities are artifacts caused by changing sample humidity, and, if required, calibration measurements only have to be performed at one humidity level. We introduce the instrumental adaption necessary for using the novel method and subsequently present proof-of-concept results of measurements in a laboratory, as well as in a ‘real-life’ environment, utilizing two different PTR-MS instruments.

Zitieren

APA

Winkler, K., Gutmann, R., Mauracher, A., Rosenkranz, B., Märk, L., & Sulzer, P. (2024). 100% humidity independent PTR-MS: Novel method and proof-of-concept *. Physica Scripta, 99(12), 121502. https://doi.org/10.1088/1402-4896/ad9362

Vancouver

Winkler K, Gutmann R, Mauracher A, Rosenkranz B, Märk L, Sulzer P. 100% humidity independent PTR-MS: Novel method and proof-of-concept *. Physica Scripta. 2024;99(12):121502. doi:10.1088/1402-4896/ad9362

BibTeX
@article{Winkler2024,
  author = {Winkler, Klaus and Gutmann, Rene and Mauracher, Andreas and Rosenkranz, Bea and Märk, Lukas and Sulzer, Philipp},
  title = {100% humidity independent PTR-MS: Novel method and proof-of-concept *},
  journal = {Physica Scripta},
  year = {2024},
  volume = {99},
  number = {12},
  pages = {121502},
  doi = {10.1088/1402-4896/ad9362}
}
Kostenlos starten →